References

Insulation & Membranes

273 sources in the library on insulation & membranes. Each one says what the document covers and what it is good for. Name a source to see which document it is and where to read it. One at a time. Page 7 of 7.

  1. supplier figure RN-AHY1GO

    SOPREMA UK (Celotex)

    Thick PIR insulation board with aluminium foil facings, boards 2400 x 1200 mm. Declared thermal conductivity (lambda D) 0.022 W/mK. Thickness range 110 mm to 200 mm. Compressive strength 140 kPa. BBA Certificate 25/7318 covers pitched roof, dry lining and floor insulation. Fire: SOPRATHERM XR4000 achieves a reaction to fire classification of Euroclass F in accordance with BS EN 13501-1.

  2. supplier figure RN-131KRM

    STEICO

    Wood fibre internal insulation board for mineral surfaces to EN 13171, designation WF - EN 13171 - T4 - CS(10\Y)50 - TR2,5 - AFr100. Declared thermal conductivity 0.038 W/(mK). Density 160 kg/m3. Water vapour diffusion resistance factor mu 5; sd 0.2 m at 40 mm, 0.3 m at 60 mm, 0.4 m at 80 mm, 0.50 m at 100 mm. Declared thermal resistance 1.05 (40 mm), 1.55 (60 mm), 2.10 (80 mm), 2.63 (100 mm) m2K/W. Compressive strength at 10% compression 0.05 N/mm2, that is greater than or equal to 50 kPa; tensile strength perpendicular to face greater than or equal to 2.5 kPa. Airflow resistance greater than or equal to 100 (kPa s)/m2. Specific heat capacity 2100 J/(kgK); biogenic carbon approximately 285 kg CO2eq/m3. Fire class (RTF) according to EN 13501-1: E.

  3. supplier figure RN-VMF4DE

    STEICO

    Wood fibre external insulation board designed to take direct render, to EN 13171 and EN 14964, designation WF - EN 13171 - T5 - DS(70,90)3 - CS(10\Y)50 - TR10 - WS1,0 - MU3. Declared thermal conductivity 0.037 W/(mK). Density 110 kg/m3. Water vapour diffusion resistance factor mu 3; sd 0.12 m at 40 mm rising to 0.90 m at 300 mm. Declared thermal resistance for Type L dry 037 (m2K/W): 2.15 (80 mm), 2.70 (100), 3.20 (120), 3.75 (140), 4.30 (160), 4.85 (180), 5.40 (200), 5.90 (220), 6.45 (240), 7.00 (260), 7.65 (280), 8.10 (300); Type M dry 1.50 (60) to 5.00 (200); Type H dry 0.90 (40) and 1.35 (60). Compression strength at least 50 kPa; tensile strength perpendicular to face at least 10 kPa. Outdoor exposure 4 weeks; specific heat capacity 2100 J/(kgK); biogenic carbon approximately 183 kg CO2eq/m3. Fire class (RTF) according to EN 13501-1: E.

  4. supplier figure RN-3O5V57

    STEICO

    Rigid wood fibre underlay and sheathing board to EN 13171. Board designations: 40 mm WF - EN 13171 - T5 - WS1,0 - CS(10\Y)200 - DS(70,90)3 - TR30; 60 to 100 mm CS(10\Y)100 - DS(70,-)2 - TR10; 120 to 240 mm CS(10\Y)50 - TR10. Declared thermal conductivity 0.043 W/(mK) at 40 mm and 0.040 W/(mK) at 60 to 80 mm. Density 180 kg/m3 at 40 mm and 140 kg/m3 at 60 to 80 mm. Declared thermal resistance (m2K/W): 0.90 (40 mm), 1.50 (60), 2.00 (80), 2.50 (100), 3.20 (120), 3.75 (140), 4.30 (160), 4.85 (180), 5.40 (200), 5.95 (220), 6.48 (240). sd 0.28 m at 40 mm to 1.68 m at 240 mm. Compressive strength at 10% compression 0.2 N/mm2 (200 kPa) at 40 mm and 0.1 N/mm2 (100 kPa) at 60 to 80 mm. Resistance to water penetration W1, outdoor exposure 8 weeks, short term water absorption 1.0 kg/m2 or less, processing temperature 5 C or above. Suitable as a roof soffit panel from 5 degrees pitch, tile roofing from above 10 degrees. Fire class (RTF) according to EN 13501-1: E.

  5. supplier figure RN-009TEM

    STEICO

    Rigid wood fibre sarking and sheathing board to EN 13171 and EN 14964, designation WF - EN 13171 - AFr100 - T5 - WS1,0 - MU5 - CS(10\Y)200 - DS(70,-)2 - TR30, EN-14964-IL. Declared thermal conductivity 0.048 W/(mK). Density 270 kg/m3. Water vapour diffusion resistance factor mu 5; sd 0.11 m at 22 mm, 0.18 m at 35 mm, 0.30 m at 60 mm. Declared thermal resistance 0.45 (22 mm), 0.70 (35 mm), 1.25 (60 mm) m2K/W. Compressive strength at 10% compression 0.20 N/mm2, that is greater than or equal to 200 kPa; tensile strength perpendicular to face greater than or equal to 30 kPa. Short term water absorption less than or equal to 1.0 kg/m2, outdoor exposure 4 weeks, suitable from a roof pitch of 14 degrees or more. Specific heat capacity 2100 J/(kgK). Fire class (RTF) according to EN 13501-1: E.

  6. supplier figure RN-OOMKQ5

    STEICO

    Flexible wood fibre batt to EN 13171, board designation WF - EN 13171 - T3 - TR1 - AFr5 - MU 2. Declared thermal conductivity 0.036 W/(mK). Density 50 kg/m3. Water vapour diffusion resistance factor mu 2. Specific heat capacity 2100 J/(kgK). Declared airflow resistance greater than or equal to 5 (kPa s)/m2. Declared thermal resistance (m2K/W) by thickness in mm: 0.80 (30), 1.10 (40), 1.35 (50), 1.65 (60), 2.20 (80), 2.75 (100), 3.30 (120), 3.85 (140), 4.40 (160), 5.00 (180), 5.55 (200), 6.10 (220), 6.65 (240). sd values 0.06 m at 30 mm rising to 0.48 m at 240 mm. Ingredients wood fibres, polyolefin fibres, ammonium sulfate; biogenic carbon approximately 82 kg CO2eq/m3. Fire class (RTF) according to EN 13501-1: E.

  7. supplier figure RN-2GTPEI

    Superglass (Etex)

    Non combustible glass mineral wool flexible slab supplied at 600 mm widths for friction fitting between common stud and joist spacings. Declared thermal conductivity (lambda) 0.032 W/mK. Manufactured at a nominal density of 32 kg/m3. Fire classification Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. Applications include light gauge steel framing between studs, party and separating walls and internal partition walls.

  8. supplier figure RN-HG2CBY

    Superglass (Etex)

    Non combustible glass mineral wool roll supplied 1200 mm wide to suit common rail and bracket systems. Declared thermal conductivity (lambda) 0.032 W/mK. Fire classification Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800128/0227. For walls and roofs of twin skin profiled metal clad systems and portable and modular buildings.

  9. supplier figure RN-2CC4VS

    Superglass (Etex)

    Non combustible glass mineral wool loft roll supplied in a shorter roll length for ease of handling, partially perforated for use between joists or as a full width layer over them. Declared thermal conductivity (lambda) 0.044 W/mK. Fire classification Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800129/0227.

  10. supplier figure RN-8K0ODQ

    Superglass (Etex)

    Non combustible glass mineral wool acoustic roll, partially perforated at 2 x 600 mm and 3 x 400 mm widths for friction fitting between common stud and joist spacings. Manufactured at a minimum density of 10 kg/m3. Declared thermal conductivity (lambda) 0.044 W/mK. Fire classification: Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800127/0227. For internal walls and floors, timber and metal stud partitions, separating walls and floors.

  11. supplier figure RN-21LSOA

    Superglass (Etex)

    Non combustible glass mineral wool roll, partially perforated for use between standard joist spacings or as a full width layer over the joists. Declared thermal conductivity (lambda) 0.040 W/mK. Fire classification Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800129/0227. Primarily for lofts and cold pitched roofs, also used between the joists of suspended timber ground floors.

  12. supplier figure RN-GC70RS

    Superglass (Etex)

    Non combustible glass mineral wool loft roll, partially perforated so it can be laid between standard joist spacings or as a full width layer over the joists. Declared thermal conductivity (lambda) 0.044 W/mK. Fire classification: deemed non combustible with a fire classification of Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. Holds CCPI Assessment Mark, certificate number 005800129/0227. Intended for new and existing cold pitched roofs and lofts.

  13. supplier figure RN-TQOT2C

    Superglass (Etex)

    BBA certified non combustible glass mineral wool cavity wall batt with a water repellent additive, supplied 455 mm wide to friction fit between standard vertical wall tie spacings. Declared thermal conductivity (lambda) 0.036 W/mK. Fire classification: Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800103/0728. Approved for full or partial fill in new external masonry cavity walls up to 25 metres in height for full fill and without height restriction for partial fill, with additional requirements above 12 metres for full fill and above 25 metres for partial fill. BBA certified for use in all UK exposure zones subject to the certificate conditions.

  14. supplier figure RN-NEMR6H

    Superglass (Etex)

    Non combustible glass mineral wool roll cut at 2 x 570 mm widths to friction fit between common stud and rafter spacings. Declared thermal conductivity (lambda) 0.032 W/mK. Fire classification: Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800130/0227. Intended for external timber frame walls, warm pitched roofs and suspended timber floors.

  15. supplier figure RN-6TAMOI

    Superglass (Etex)

    Non combustible glass mineral wool roll for external timber frame walls, warm pitched roofs and suspended timber floors. Declared thermal conductivity (lambda) 0.035 W/mK. Fire classification Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800130/0227.

  16. supplier figure RN-TOS2R5

    Thermafleece (Eden Renewable Innovations Ltd)

    High density sheep wool rich insulation slab, 75% wool with recycled fibres, 20 to 25% recycled content. Density 31 kg/m3. Thermal conductivity 0.035 W/mK. Slabs 1200 mm long in 390 and 590 mm widths, thicknesses 50, 70 and 90 mm with a plus or minus 5 mm tolerance. Published thermal resistance (m2K/W): 50 mm 1.43, 70 mm 2.00, 100 mm 2.86, 140 mm 4.00, 190 mm 5.43, 240 mm 6.86. Fire Classification EuroClass E; flammability and smoulder resistance to BS 5803-4 pass. Vapour resistivity 9 MNs/gm. Specific heat capacity 1800 J/kgK. Water absorption at 100% RH 24% w/w. Sound reduction Rw 41 dB, NRC 1.10 at 90 mm. Dimensional stability to EN 1604 pass, EPD registration S-P-04468. Cradle to gate A1-A3 carbon 0.05 kg CO2e per functional unit. Thermafleece states UltraWool is not suitable for use as a cavity barrier.

  17. supplier figure RN-PLXFFS

    Unilin Insulation (formerly Xtratherm)

    Full fill cavity board with a composite foil inner facing and a HIPs outer facer, 1200 x 450 mm, thicknesses 100, 110, 125 and 150 mm. Thermal conductivity 0.021 W/mK. Compressive strength CS(10Y) 100 kPa. Reaction to fire: Euroclass F. Typical wall U-values to EN ISO 6946:2017 for plasterboard on dabs, 100 mm inner leaf blockwork, CT/PIR, unventilated cavity and brick: with 1.13 W/mK blockwork 0.19 (100 mm), 0.18 (110), 0.16 (125), 0.13 (150); with 0.46 blockwork 0.19, 0.17, 0.15, 0.13; with 0.15 blockwork 0.18, 0.16, 0.15, 0.12 W/m2K.

  18. supplier figure RN-WYD11B

    Unilin Insulation (formerly Xtratherm)

    Rigid polystyrene board cut from moulded blocks, 2400 x 1200 mm and 1800 x 1200 mm. Thermal conductivity 0.035 W/mK. Compressive strength CS(10Y) 100 kPa. Thickness tolerance class T2. Reaction to fire: Euroclass F. Covered by BBA 24/7224 (2024), with a DoP and an EPD published on the same page.

  19. supplier figure RN-MBGE96

    Unilin Insulation (formerly Xtratherm)

    Width variable pitched roof board with composite foil facers both sides, 1200 x 370 mm, thicknesses 100, 125 and 150 mm. Thermal conductivity 0.023 W/mK. Reaction to fire: Euroclass F. Typical roof U-values to EN ISO 6946 for an unvented sloped roof with rafters at 400 mm centres and a 25 mm void, combined with an under rafter layer: Rafterloc 100 mm gives 0.20 with 30 mm under, 0.18 with 40 mm, 0.16 with 50 mm, 0.15 with 60 mm, 0.14 with 70 mm; 125 mm gives 0.17 to 0.13; 150 mm gives 0.15 to 0.12 W/m2K. An approved vapour permeable membrane is required.

  20. supplier figure RN-9OK5VK

    Unilin Insulation (formerly Xtratherm)

    Phenolic partial fill cavity board with composite foil facings both sides, 1200 x 450 mm, thicknesses 75, 80 and 100 mm. Thermal conductivity 0.019 W/mK. Compressive strength CS(10Y) 100 kPa. Reaction to fire: Euroclass D-s1, d0. Typical wall U-values calculated to EN ISO 6946:2017 for plasterboard on dabs, 100 mm inner leaf blockwork, SR019/CW, low emissivity unventilated cavity and brick.

  21. supplier figure RN-F98532

    Unilin Insulation (formerly Xtratherm)

    Phenolic partial fill cavity board with composite foil facings both sides, 1200 x 450 mm, thicknesses 50 and 60 mm. Thermal conductivity 0.021 W/mK. Compressive strength CS(10Y) 100 kPa. Reaction to fire: Euroclass D-s1, d0. An IGBC certified EPD is available.

  22. supplier figure RN-4J203Z

    Unilin Insulation (formerly Xtratherm)

    Phenolic thermal laminate with composite glass tissue facings, 2400 x 1200 mm, overall thicknesses 37.5, 50.5, 62.5, 72.5 and 82.5 mm. Thermal conductivity 0.021 to 0.023 W/mK (phenolic only). Compressive strength not applicable. Reaction to fire: Euroclass B-s1, d0. Unilin states the wider Safe-R 019 range reaches 0.019 W/mK.

  23. supplier figure RN-KVHEN8

    Unilin Insulation (formerly Xtratherm)

    Phenolic soffit insulation board with composite foil facings, 2400 x 1200 mm, thicknesses 75, 80, 100 and 120 mm. Thermal conductivity 0.019 W/mK. Compressive strength CS(10Y) 100 kPa. Reaction to fire: Euroclass C-s2, d0. Typical U-values to EN ISO 6946:2017 on a 200 mm concrete soffit: 75 mm 0.25, 80 mm 0.23, 100 mm 0.19, 120 mm 0.16 W/m2K.

  24. supplier figure RN-46NYD5

    Unilin Insulation (formerly Xtratherm)

    Non combustible stone wool slab for ventilated facade, rainscreen, framing and curtain walling, 1200 x 600 mm, thicknesses 50, 75, 100, 120, 150, 180 and 200 mm. Thermal conductivity 0.036 W/mK. Reaction to fire: Euroclass A1. Published R-values (m2K/W): 50 mm 1.35, 75 mm 2.05, 100 mm 2.75, 120 mm 3.45, 150 mm 4.15, 180 mm 5.00, 200 mm 5.55.

  25. supplier figure RN-9MR12L

    Unilin Insulation (formerly Xtratherm)

    Jointed PIR floor board with composite foil facers both sides, 2400 x 1200 mm, thicknesses 75, 100, 125, 140 and 150 mm. Thermal conductivity 0.021 W/mK. Compressive strength 140 kPa. Reaction to fire: Euroclass F. Typical ground supported floor U-values to EN ISO 6946:2017 vary with the perimeter to area ratio; at 75 mm the U-value runs 0.17 W/m2K at P/A 0.30 up to 0.21 W/m2K at P/A 0.80.

  26. supplier figure RN-HLFQBO

    Unilin Insulation (formerly Xtratherm)

    Enhanced PIR full fill cavity board with textured foil facings both sides, 1200 x 450 mm, thicknesses 90, 100, 115 and 140 mm. Thermal conductivity 0.021 W/mK. Compressive strength CS(10Y) 120 kPa. Reaction to fire: Euroclass E. An IGBC certified EPD is available.

  27. supplier figure RN-C2BW5M

    Unilin Insulation (formerly Xtratherm)

    PIR partial fill cavity board with composite foil facings both sides, tongue and groove, 1200 x 450 mm. Thicknesses 60, 70, 80, 100, 110, 120 and 125 mm. Thermal conductivity 0.022 W/mK. Compressive strength CS(10Y) 120 kPa. Reaction to fire: Euroclass F. Covered by BBA 23/6997 (2026).

  28. supplier figure RN-BCR1ZD

    Unilin Insulation (formerly Xtratherm)

    PIR roof board with composite foil facings both sides, 2400 x 1200 mm. Thicknesses 25, 30, 40, 50, 60, 70, 75, 80, 90, 100, 125 and 150 mm. Thermal conductivity 0.022 W/mK. Compressive strength CS(10Y) 140 kPa. Reaction to fire: Euroclass F. Covered by BBA 23/6997 (2026).

  29. supplier figure RN-0FPBZN

    Unilin Insulation (formerly Xtratherm)

    PIR wall board for timber frame walls with composite foil facers both sides, 2400 x 1200 mm, thicknesses 25, 30, 40, 50, 60, 70, 75, 80, 100, 110, 125 and 150 mm. Thermal conductivity 0.022 W/mK. Compressive strength CS(10Y) 140 kPa. Reaction to fire: Euroclass F. Published R-values (m2K/W): 25 mm 1.10, 40 mm 1.80, 50 mm 2.25, 60 mm 2.70, 80 mm 3.60, 100 mm 4.50, 120 mm 5.65.

  30. supplier figure RN-9TK54X

    Unilin Insulation (formerly Xtratherm)

    PIR thermal laminate bonded to 12.5 mm plasterboard, kraft paper facings, 2400 x 1200 mm. Overall thicknesses 37.5, 50.5, 62.5, 72.5, 82.5 and 92.5 mm. Thermal conductivity 0.022 W/mK (PIR only). Reaction to fire: Euroclass B s1 d0. Covered by BBA 23/6997 (2026).

  31. supplier figure RN-4TS29G

    Unilin Insulation (formerly Xtratherm)

    Rigid extruded polystyrene board, 1250 x 600 mm, thicknesses 30, 40, 50, 60, 80, 100, 120, 140 and 160 mm. Thermal conductivity 0.033 to 0.035 W/mK. Compressive strength CS(10Y) 300 kPa. Reaction to fire: Euroclass E. Published R-values (m2K/W): 30 mm 0.90, 40 mm 1.20, 50 mm 1.50, 60 mm 1.80, 80 mm 2.25, 100 mm 2.85, 120 mm 3.40, 140 mm 4.00, 160 mm 4.25. The range is also available in 500 kPa and 700 kPa grades.

  32. supplier figure RN-CMGNLX

    Unilin Insulation (formerly Xtratherm)

    High performance extruded polystyrene board, 1250 x 600 mm, thicknesses 30, 40, 50, 60, 80, 100 and 120 mm. Thermal conductivity 0.033 to 0.035 W/mK. Compressive strength CS(10Y) 500 kPa. Reaction to fire: Euroclass E. Published R-values (m2K/W): 30 mm 0.90, 40 mm 1.20, 50 mm 1.50, 60 mm 1.80, 80 mm 2.25, 100 mm 2.85, 120 mm 3.40.

  33. supplier figure RN-H1V08T

    Wickes

    the retail price Wickes publishes for Glidevale Protect AH5 Part L Hinge Down Insulated Loft Hatch 600 x 520mm, which is the supply figure the cost book records for this item