76 sources in the library on room by room. Each one says what the document covers and what it is good for. Name a source to see which document it is and where to read it. One at a time. Page 2 of 2.

  1. very strong RN-O31MAS

    Scottish Government

    The 714-page handbook that carries Scotland's own numbers, which differ from England's. Table 4.3 sets private stair geometry at minimum rise 100 mm, maximum rise 220 mm, minimum going 225 mm, tread not less than the going and maximum pitch 42 degrees; Table 4.4 sets any other stair at maximum rise 170 mm, minimum going 250 mm and maximum pitch 34 degrees; going plus twice the rise must be between 550 mm and 700 mm, tapered treads at least 50 mm at the narrow end, a flight generally 3 to 16 rises. Table 4.5 puts effective width at 900 mm for a private stair, 800 mm where a continuous handrail is on both sides, 600 mm where it serves only sanitary accommodation or one room, and 1.0 m for any other stair, with stringer or newel projection no more than 30 mm. Clause 4.3.15 sets handrail height at 840 mm to 1.0 m above the pitch line, 4.3.16 headroom at 2.0 m, and 4.3.17 points spiral and helical stairs to BS 5395-2:1984. Table 5.1 sets separating element performance at 56 dB DnT,w airborne and 56 dB L'nT,w impact for new build, relaxed to 53 dB and 58 dB for conversions of traditional buildings.

  2. very strong RN-8T0SVC

    Scottish Government (gov.scot)

    Scotland's equivalent of the Approved Documents, and the reason a note that quotes only English rules is wrong for a fifth of the UK. This edition is in force from 6 April 2026 and applies to building warrants submitted on or after that date and to work not requiring a warrant commenced from that date. It gives guidance on achieving the standards set in the Building (Scotland) Regulations 2004, arranged in sections rather than parts: section 3 environment (ventilation, drainage, condensation), section 4 safety (electrical safety and installations, glazing and danger from accidents, including clause 4.13 which invokes PAS 24 for security), section 6 energy (U-values for windows and doors) and section 7 sustainability. Scotland uses a building warrant and a completion certificate rather than a building notice, and has no Part P competent person scheme equivalent, so electrical work is covered by the warrant system instead.

  3. very strong RN-N71WWH

    Scottish Government Building Standards Division

    Scotland's own conservatory guidance, published 25 November 2015 as a 41 page PDF, giving guidance on meeting the Building (Scotland) Regulations 2004 as amended for simple conservatories built onto existing houses. A note that quotes the English 30 square metre building regulations exemption should flag that Scotland runs a separate warrant regime with its own conservatory rules, and point readers here. Issued by the Building Standards Division, Denholm House, Almondvale Business Park, Livingston, telephone 0131 244 6511.

  4. very strong RN-43Q4DG

    The National Archives (legislation.gov.uk)

    The definitive list of what counts as a statutory nuisance in England and Wales, which is the legal hook for most neighbour and building-work complaints. Section 79(1) names, among others: (a) any premises in such a state as to be prejudicial to health or a nuisance, which is the route used against damp and disrepair; (b) smoke emitted from premises; (c) fumes or gases emitted from premises; (d) dust, steam, smell or other effluvia arising on industrial, trade or business premises; (e) any accumulation or deposit; (fb) artificial light emitted from premises, which covers security lighting; (g) noise emitted from premises; and (ga) noise from a vehicle, machinery or equipment in a street. Each limb requires the matter to be prejudicial to health or a nuisance. Section 79(1) also places a duty on every local authority to inspect its area for statutory nuisances and, where a person living in its area complains, to take such steps as are reasonably practicable to investigate. Section 79(1A) excludes matters caused by land being in a contaminated state, and section 79(2) excludes Crown defence premises from the smoke, artificial light and noise limbs.

  5. very strong RN-9WXESB

    The National Archives (legislation.gov.uk)

    The private route that lets an individual go to the magistrates' court directly, without waiting for the council, when aggrieved by a statutory nuisance; in Scotland the equivalent is a summary application to the sheriff. If satisfied the nuisance exists, or that though abated it is likely to recur, the court must make an order requiring the defendant to abate it within a specified time and to execute any works necessary, or prohibiting recurrence, and may also impose a fine not exceeding level 5 on the standard scale. Section 82(3) allows the court, where the nuisance makes premises unfit for human habitation, to prohibit their use for habitation until they are made fit. Section 82(4) fixes who is sued: normally the person responsible, but (b) where the nuisance arises from any defect of a structural character it is the owner of the premises, and (c) where the person responsible cannot be found, the owner or occupier. Section 82(5) makes each of several responsible persons liable even where their own contribution would not by itself be a nuisance.

  6. very strong RN-2Z6CJF

    The National Archives (legislation.gov.uk)

    SI 1988/1324, the flammability regime that applies to the soft furnishings and any loose upholstered elements a fitted-furniture project buys in. It revoked the Upholstered Furniture (Safety) Regulations 1980 and its 1983 amendment and imposes requirements on new domestic furniture, including garden furniture that may be used indoors and furniture for use in caravans, subject to exceptions for certain furniture. Some requirements also apply to second-hand furniture, and the regulations do not apply to goods for export. The point for a note is that these regulations bite on furniture supplied in the course of a business, not on the building fabric.

  7. very strong RN-I5NTO7

    UK Health Security Agency

    UKHSA's cold weather health guidance, first published 2 November 2012 and last updated 28 April 2026, applying to England, reference GOV-15292. Establishes the alerting framework a heating or insulation note can anchor to: the UKHSA Cold-Health Alerting system is operated by the Met Office and runs from 1 November to 31 March each year, and this guidance forms the cold weather part of UKHSA's Adverse Weather and Health Plan, whose aim is to protect health and reduce harm from adverse cold weather. Issued in several formats including an HTML main version, an easy read PDF of 8 pages, a British Sign Language video, a two-page print version of top tips, and a poster, with easy-read translations added on 28 April 2026 in Arabic, Bengali, Gujarati, Hindi, Italian, Kutchi, Punjabi, Portuguese, Somali, Tamil and Urdu.

  8. very strong RN-Y8BXXY

    UK Health Security Agency and Centre for Climate and Health Security

    UKHSA guidance published 7 August 2025, applying to England, on the allergens and irritants in indoor air, useful for any note that claims a renovation improves or harms air quality. States that indoor bioaerosols can contribute up to 34 per cent of indoor air pollution, and that people in Western countries spend the majority of their time indoors. Identifies the protein-based allergens as mould spores, which thrive in damp poorly ventilated spaces such as bathrooms and arise from leaks, condensation, poor heating or inadequate ventilation; house dust mites, which thrive in warm humid environments in bedding, carpets and upholstered furniture; and pet dander from skin flakes, urine and saliva. Separately names non-protein respiratory irritants: volatile organic compounds emitted by paints, cleaning agents and air fresheners, and particulate matter from cooking, smoking and open solid-fuel fireplaces. Warns that energy efficiency and adaptation measures can have unintended consequences for indoor environmental quality, and that poorly installed mechanical ventilation can worsen air quality.

  9. very strong RN-L7ESTP

    Welsh Government

    The Welsh route to funded adaptations, which differs from England in having a second scheme alongside the Disabled Facilities Grant. A Welsh applicant can apply for support from one or more of the ENABLE support for living independently scheme and the Disabled Facilities Grant, whereas an English applicant has the Disabled Facilities Grant alone. The listed adaptations are widening doors and installing ramps, improving access to rooms and facilities such as stair lifts or a downstairs bathroom, providing a heating system suitable for the applicant's needs, and adapting heating or lighting controls to make them easier to use. Part of the Welsh Government's Home safety, repairs and adaptation collection, with parallel guides for social housing tenants and for adapting a home before returning from hospital.

  10. very strong RN-ZHZCV2

    Welsh Government

    The Welsh fire safety guidance that governs fire doors, protected stairways and open plan layouts in Wales. First published 27 August 2015 and last updated 19 June 2025, it is issued as two PDFs, Approved Document B dwellinghouses at 5 MB and buildings other than dwellinghouses at 6 MB, and must be read with four amendment slips, the most recent applicable from 20 December 2025. A note that says an FD30 door is needed at the head or foot of a loft stair, or that an open plan ground floor triggers a sprinkler or an escape window, should cite the Welsh document for a Welsh reader.

  11. very strong RN-U1RMCM

    Welsh Government

    The Welsh ventilation guidance, which sets the extract rates a new utility room, boot room, en suite or downstairs WC has to meet in Wales. First published 3 April 2017 and last updated 7 April 2026, the page carries Approved Document F volume 1 for dwellings as a 910 KB PDF and volume 2 at 488 KB, plus the September 2013 amendment slip. Critically for date-sensitive notes, it also carries a new Approved Document F volume 1 for dwellings that takes effect on 4 March 2027, which is a different commencement date from the English 2026 edition, so a UK-wide note must not treat the two nations as switching over together.

  12. very strong RN-GB8FSC

    Welsh Government

    The Welsh guidance covering sanitary provision, hot water safety and water efficiency, the part that governs adding a WC, basin, shower or en suite. First published 5 April 2017 and last updated 10 May 2023, issued as a single 1 MB PDF and to be read with the September 2013 amendment slip. A note that quotes the English water efficiency calculation or hot water safety requirements for a new bathroom should check the Welsh document separately, because Wales sets its own water efficiency standard for new dwellings.

  13. very strong RN-UHBO2G

    Welsh Government

    The Welsh energy efficiency guidance, first published 14 June 2016 and last updated 7 April 2026. It carries volume 1 for dwellings and volume 2 for other buildings as current PDFs, and a new Approved Document L volume 1 for dwellings that takes effect on 4 March 2027. Any note quoting fabric U-value targets for a floor, wall, roof or a conservatory's thermal separation should state which nation the figure belongs to, since Wales publishes its own Part L with its own commencement dates rather than adopting the English edition.

  14. very strong RN-HCKL9C

    Welsh Government

    The Welsh Part M, and the document that decides whether a downstairs WC may be removed in a renovation. Section 10 sets the objective as a WC in the entrance storey located so that no stair need be negotiated to reach it from the habitable rooms in that storey; where the entrance storey has no habitable rooms, a WC in either the entrance storey or the principal storey is reasonable. Paragraph 10.3 says requirement M4 is satisfied if a WC is provided on that basis, the door to the WC compartment opens outwards and is positioned to let a wheelchair user reach the WC with a clear opening width per Table 4, and the compartment gives clear space for wheelchair access with the washbasin positioned so it does not impede access, per Diagrams 31 and 32. It also states plainly that it will not always be practical for the wheelchair to be fully accommodated inside the compartment. Crucially, the guidance on material alterations gives the worked example: removing a WC in the entrance storey of a dwelling is a material alteration if it is the only WC in that storey and the storey contains habitable rooms, and it must not be removed or made less compliant unless another WC no less compliant is provided in that storey.

  15. strong RN-2RQT3P

    BSI

    BS 6465-1:2006+A1:2009, in effect from 31 March 2006 with Amendment 1 in 2009, prepared by Technical Committee B/503 Sanitary appliances, ISBN 978 0 580 67116 6, current. It is the code of practice for designing sanitary facilities and setting the scale of provision of sanitary and associated appliances, and it supersedes BS 6465-1:2006. It sits in a suite of four standards: Part 1 scales of provision, Part 2 space recommendations, Part 3 selection, installation and maintenance, Part 4 provision of public toilets. It traces back to CP 305-1 first published July 1952, with the third edition issued as BS 6465-1 in February 1984 and the fifth in March 2006. Use it to establish how many WCs and basins a dwelling should have.

  16. strong RN-XEZK0G

    BSI

    BS 6465-2:2017, in effect 31 July 2017, prepared by Technical Committee B/209 General building codes, current. It supersedes BS 6465-2:1996, which is withdrawn. It gives recommendations for the space required around all sanitary appliances so they are convenient in use and can be maintained and cleaned, which is the source for activity space and clearance dimensions in front of a WC, basin, bath and shower. It is one of a suite of four: Part 1 scales of provision, Part 3 selection and installation, Part 4 public toilets. As a code of practice its recommendations are guidance rather than specification, so a claim should be worded as recommended clearance, not a legal minimum.

  17. strong RN-ATZB5V

    BSI

    The standard behind internal noise level targets quoted for bedrooms and living rooms, published 28 February 2014 and current. BS 8233 gives guidance on the control of noise in and around buildings and applies to the design of new buildings and to refurbished buildings undergoing a change of use. It expressly does not cover assessing the effect of changes in external noise on occupants of an existing building, specialist applications such as auditoria and cinemas, which fall to BS ISO 9568, vibration control except where it appears as radiated sound, or noise breaking out of a building to external receptors. A note about soundproofing an existing room should therefore treat it as a design reference, not as a compliance test.

  18. strong RN-N6ZC3R

    BSI

    BS EN 520:2004+A1:2009, published 22 November 2004 with Amendment 1 in 2009, committee B/544, under review. Clause 1 specifies the characteristics and performance of gypsum plasterboards for building construction, including boards intended for secondary manufacturing operations and boards designed to receive either direct surface decoration or gypsum plaster. The product performance characteristics it covers are reaction to fire, water vapour permeability, flexural strength (breaking load), impact resistance and thermal resistance. It separates out the characteristics that belong to the assembled system rather than the board alone, and are measured on assemblies simulating end use conditions: shear strength, fire resistance, impact resistance, direct airborne sound insulation and acoustic absorption. It also covers additional technical characteristics important for the use and acceptance of the product by the construction industry, the reference tests for them, and evaluation of conformity. This is the standard that defines the plasterboard type letters a merchant lists, so cite it for fire-resistant, moisture-resistant and higher-density board claims.

  19. strong RN-2N8PYB

    BSI (British Standards Institution)

    STATUS: WITHDRAWN on 29 October 2025, a very recent change. BS 5266-1:2016 was published 31 May 2016 and gave the code of practice for the design, installation and wiring of electrical emergency lighting, covering three purposes: assisting occupants to leave a building in an emergency, protecting those who remain inside, and allowing operations to continue if normal lighting fails, including recommendations for areas with fixed seating. Its scope covers common access routes in blocks of flats but EXCLUDES single family dwellings, a distinction a note should keep when it tells a homeowner that emergency lighting is required. Because it was withdrawn in October 2025, any note citing BS 5266-1:2016 needs checking against the current edition. Catalogue page confirms number, title, publication date, withdrawal date and scope but does not name the replacement.

  20. strong RN-I3E8M9

    BSI (British Standards Institution)

    STATUS: CURRENT. BS 6222-2:2009+A1:2017 (base edition published 31 January 2009, amended 2017) specifies the performance requirements and test methods for the strength and durability of the structure of domestic and residential fitted kitchen units, peninsular units, island units and breakfast bars. It EXCLUDES free standing units and storage furniture for other applications, and it does not cover worktop or storage unit safety, which sit in BS EN 14749:2016+A1:2022, Furniture. Domestic and kitchen storage units and kitchen worktops. Safety requirements and test methods. Together with BS EN 1116:2018 for coordinating sizes this is the pair a kitchen note should cite: BS EN 1116 for whether a unit fits, BS 6222-2 for whether its carcass will survive use. Catalogue page confirms number, title, date, status and scope; the tests are paywalled.

  21. strong RN-445W51

    BSI (British Standards Institution)

    The accessibility code of practice that Approved Document M sits alongside. Paywalled, so only the catalogue page is public; it confirms BS 8300-2:2018, published 31 January 2018, status Current, and that it is part 2 of a two-part standard, with BS 8300-1:2018 (also published 31 January 2018, also Current) covering the external environment including parking, setting-down points, access routes and approaches to entrances. Part 2 covers external features affecting external access routes, and building interiors including entrances, reception facilities, horizontal and vertical movement and building facilities. Crucially for a home renovation note, the catalogue page states plainly that BS 8300-2 does NOT apply to individual dwellings; its residential scope is nursing, residential and care homes, student accommodation and the COMMON PARTS of blocks of flats. It also confirms the recommendations apply largely to new buildings but can be used to assess and improve existing ones, and that the extent to which they apply to listed and historic buildings is decided case by case.

  22. strong RN-TG59SM

    BSI (British Standards Institution)

    STATUS: WITHDRAWN on 31 October 2015, superseded by BS 9991:2015 (and since by a further revision). BS 9991:2011 was published 31 December 2011 and itself superseded BS 5588-1:1990. It gave the code of practice for fire safety in residential buildings, covering dwellings, residential accommodation blocks for up to six people and sheltered and extra care housing, applying to new design and to material alterations, extensions and changes of use, across ten sections covering means of escape, stairs, firefighting access, active fire protection, construction, mechanical systems, ancillary accommodation and management. It excludes hotels, caravans, hospitals, care homes, detention facilities, hostels and houses in multiple occupation. This is the standard a loft conversion note reaches for when discussing protected stairs and escape windows, so citing the 2011 edition is citing a withdrawn one. Catalogue page confirms number, title, publication date, withdrawal date, supersession and scope.

  23. strong RN-XT8DUF

    BSI (British Standards Institution)

    STATUS: CURRENT. BS 9999:2017 was published 31 January 2017 and supersedes BS 9999:2008, which is withdrawn. It gives the code of practice for fire safety in the design, management and use of buildings, aimed at life safety for occupants and firefighters with property and business protection as secondary objectives. The 2017 revision added a design process flowchart, brought in watermist suppression systems, revised smoke and heat control guidance, added recommendations for fire curtain barriers and updated the shopping complex provisions. Crucially for a home renovation note, it EXCLUDES individual dwellinghouses, and has limited application to specialist buildings such as hospitals and places of lawful detention, so it is the wrong standard to cite for a house: use Approved Document B Volume 1 for dwellings and BS 9991 for residential buildings. Catalogue page confirms number, title, date, status, supersession and scope.

  24. strong RN-1PGUPY

    BSI (British Standards Institution)

    STATUS: CURRENT. BS EN 1116:2018 was published 28 February 2018, is identical to EN 1116:2018, ISBN 978 0 580 94536 6, and supersedes BS EN 1116:2004. It specifies coordinating sizes for kitchen units, worktops, recess panelling, furniture fronts and decorative panels, and for kitchen appliances (white goods and ovens) and further installation elements such as sinks, giving the height, width and depth dimensions and the space needed to integrate an appliance into a unit. This is the standard behind the 600 mm module and standard carcass depths that make an integrated appliance fit a run of units, and it is what a note should cite when explaining why a replacement dishwasher or oven fits an existing housing. It does not cover commercial kitchens in hotels or restaurants. Catalogue page confirms number, title, date, status, ISBN and scope; the dimension tables are paywalled.

  25. strong RN-QWQAQG

    BSI (British Standards Institution)

    STATUS: CURRENT. BS EN 13126-5:2011+A1:2014 (base edition published 31 December 2011) specifies the requirements and test methods for the durability, strength, security and function of devices that restrict the opening of windows and door height windows, applying to restrictors on tilt and turn, pivot, casement and top hung windows. The classification is the useful part for a note: it separates SAFETY limiting restrictors from CHILD SAFETY limiting restrictors, with distinct requirements aimed at reducing the risk of accidental falls, which is what a note should cite when it says a window above ground floor level needs a child resistant restrictor rather than any restrictor. It applies only where the restriction falls within the specification in Annex A, E or G of EN 1191:2012 for the manufacturer's intended use. Catalogue page confirms number, title, date, status, the two restrictor categories and scope.

  26. strong RN-KP1GD0

    BSI (British Standards Institution)

    STATUS: WITHDRAWN on 28 February 2014. BS EN ISO 140-4:1998 was published 15 October 1998 and gave the methods for measuring the airborne sound insulation of interior walls, floors and doors between two rooms on site, producing frequency dependent values that are converted to a single number rating using ISO 717-1 so that performance can be compared against a specification. It was replaced by the BS EN ISO 16283 series, with BS EN ISO 16283-1 covering field measurement of airborne sound insulation, and the laboratory measurements formerly in other parts of BS EN ISO 140 moving to BS EN ISO 10140. Any note describing a pre completion sound test to BS EN ISO 140 is quoting a standard withdrawn in 2014: Approved Document E testing is now to the BS EN ISO 16283 series with rating to BS EN ISO 717. Catalogue page confirms number, title, publication date, withdrawal date and scope.

  27. strong RN-LO5VGF

    BSI (British Standards Institution)

    STATUS: CURRENT. BS EN ISO 717-1:2020 was published 31 December 2020 and supersedes BS EN ISO 717-1:2013, which is withdrawn. It defines the single number quantities for airborne sound insulation in buildings and building elements, that is the method for converting a frequency dependent measurement into one figure, and it covers spectrum adaptation terms for different noise sources including internal noise and external traffic noise. The 2020 revision moved content in from ISO 10140-1:2016 and ISO 10140-5:2010 and updated the references. This is the standard behind the Rw, DnT,w and DnT,w + Ctr figures quoted in soundproofing notes and in Approved Document E, and its companion BS EN ISO 717-2:2020 does the same for impact sound (Lnw, LnT,w). Catalogue page confirms number, title, date, status, supersession and scope; the calculation method is paywalled.

  28. strong RN-R62UPB

    Chartered Institution of Building Services Engineers

    The core CIBSE reference for design criteria and calculation methods, cited whenever a note needs an authority for indoor design temperatures, fabric performance or heat loss and ventilation sizing. Publisher CIBSE, status Active, 402 pages, publication date March 2015 with a 2021 update, ISBN 9781906846541. The text is paywalled at GBP 200 plus VAT standard rate for the book and GBP 150 plus VAT for the download, free to CIBSE members, so only the catalogue page is public. The page confirms the scope: design criteria and calculation methods covering fabric performance, heating and ventilation system sizing, methods for thermal comfort evaluation and energy demand. Two currency notes recorded on the page matter for anyone citing it: Chapter 2 of Guide A supersedes TM34 Weather data with climate change scenarios (2004), and the Guide references BS EN 779:2012 for air filters, which has since been superseded by BS EN ISO 16890. The supplementary data files are downloadable free and include external design data, UK wind roses (Figure 2.8), solar irradiation on inclined planes (Table 2.12), sol-air temperatures (Table 2.14) and UK cooling load tables (Tables 5.16 and 5.17).

  29. strong RN-U3IDLH

    Chartered Institution of Building Services Engineers

    TM59 is the dynamic thermal modelling methodology that Approved Document O Section 2 names as its alternative to the simplified glazing and free-area route, so it is a required citation for any note about overheating. This page is for the 2026 edition, published July 2026, 39 pages, ISBN 9781912034123, and it is FREE to download at both standard and member rate, unusually for CIBSE. The critical compliance point stated on the page: TM59 (2017) is still the version required for compliance with Part O, and CIBSE recommends TM59 (2026) only for industry best practice while it discusses with the Building Safety Regulator how the updated weather files and new version might be incorporated into the Approved Documents. So a note must not tell a reader that the 2026 edition satisfies Part O. The 2026 update adds a new bedroom overheating criterion based on Loughborough University research, updated ceiling fan modelling presenting fans as an effective passive comfort solution, and mandates that all homes be tested under unconstrained conditions using 2050s weather data. TM59 applies to houses, apartments, sheltered accommodation, care homes, student accommodation, prisons and bedrooms in hotels and hospitals, and covers new dwellings and major refurbishments. The page also records that in 2026 the Climate Change Committee raised risks to buildings and communities from heat to its highest category, Critical Action needed.

  30. strong RN-5XVQAQ

    Electrical Safety First

    States that sockets are not allowed in a bathroom or shower room, apart from shaver supply units, unless they can be fitted at least 2.5 m from the edge of a bath or shower tray. Shaver points are permitted within that 2.5 m provided they are SELV or conform to BS EN IEC 61558-2-5. Recommends a ceiling-mounted pull-cord switch in preference to a wall light switch because of dampness and wet hands. Confirms all circuits in or passing through bathrooms or shower rooms must be protected by an RCD. General guidance keeps outlets at least 30 cm from water or heat sources.

  31. good RN-RYJ6RE

    British Healthcare Trades Association

    The UK trade association for healthcare and assistive technology suppliers, which is the body behind stairlifts, through-floor lifts, level access showers and other adaptations a renovation may include. It runs a member directory, a Chartered Trading Standards Institute approved code of practice with a consumer complaints and arbitration route, consumer advice and guidance, and a government grants finder that is a legitimate starting point for a reader asking who pays for an adaptation. Contact 020 7702 2141. Use it for finding a code-bound supplier and for the complaint route, not for prices.

  32. good RN-CK4M6V

    Finishes and Interiors Sector

    The trade body uniting the finishes and interiors supply chain, whose stated aim is to raise standards and improve quality, safety and sustainability in the 13 billion pound finishes, fit-out and interiors sector. Membership covers contractors, manufacturers and suppliers, all vetted against strict quality and safety criteria. Its Knowledge Hub holds Technical Resources, Building Safety Act guidance, health and safety resources, sustainability resources, a Digital Construction toolkit, the Acoustic Verification Scheme, Support for Specifiers and a British Standards section. Other main sections are the Member Directory, Project Library, Skills Hub, Membership Hub and SpecFinish. Use it as the trade authority for drylining, partition and suspended ceiling workmanship, and its Acoustic Verification Scheme when a note claims a partition achieves a stated sound reduction.

  33. good RN-SYJKS7

    Furniture Industry Research Association

    The UK research association for the furniture supply chain, the body behind furniture testing, ergonomics and compliance guidance that a note on fitted or built-in furniture would cite for standards and flammability compliance. Membership is open to retailers, manufacturers and international organisations, and it publishes reports, guides and business templates through its bookshop, with testing and consultancy delivered through its service provider Fira International Ltd. Use it as the route to furniture test standards rather than as a source of prices.

  34. good RN-9FCDRK

    Glass and Glazing Federation

    The glazing trade body's consumer guide to conservatories and orangeries, with a conservatory guide, glazing insights and advice articles, and a member finder. It sets out the recognised style families a note should use when it names a conservatory type, including the Victorian conservatory with its ridged roof and multi-faceted end wall, and covers frame and glazing material choices. Useful as the trade reference for the distinction between a conservatory and an orangery, which matters because that distinction changes the roof-to-wall ratio and therefore whether the building regulations exemption still applies. Contact +44 (0)207 939 9100.

  35. fair RN-2RGEMP

    NHS

    The clinical authority for what carbon monoxide does and how many alarms a home needs. Lists symptoms as headache, dizziness, nausea or vomiting, weakness, tiredness and confusion, chest and muscle pain, shortness of breath, flushing and loss of vision, and notes the tell-tale pattern that symptoms worsen in an affected room and improve on leaving the building. Names the appliances that can produce carbon monoxide when badly installed, faulty or poorly maintained: gas boilers, gas cookers and clay ovens, gas or paraffin heaters, wood, gas and coal fires and portable generators, plus barbecues or camping stoves used indoors and engines run in a garage. The prevention advice is specific: get a carbon monoxide alarm for each room of the home containing an appliance that burns gas, oil, coal or wood, have appliances properly installed and serviced regularly by a qualified and registered engineer, and keep chimneys and flues clear. Directs readers to call NHS 111 for suspected poisoning and 999 for breathing difficulty, sudden confusion or loss of consciousness.

  36. supplier figure RN-L7ZDAH

    Barrisol

    the manufacturer's own conditions of installation for Barrisol stretch ceilings: that they may only be installed in sealed, clean, dust free and dry buildings, that cartons exposed to cold must rest 24 hours in the warm before opening, that only authorised factory trained installers should install or dismantle them, and that embedded spotlights must not exceed 50W, need an insulating ring above 50 degrees C, and are incompatible above 60 degrees C at the metallic rose