References

Cladding & Render

85 sources in the library on cladding & render. Each one says what the document covers and what it is good for. Name a source to see which document it is and where to read it. One at a time. Page 3 of 3.

  1. supplier figure RN-VMF4DE

    STEICO

    Wood fibre external insulation board designed to take direct render, to EN 13171 and EN 14964, designation WF - EN 13171 - T5 - DS(70,90)3 - CS(10\Y)50 - TR10 - WS1,0 - MU3. Declared thermal conductivity 0.037 W/(mK). Density 110 kg/m3. Water vapour diffusion resistance factor mu 3; sd 0.12 m at 40 mm rising to 0.90 m at 300 mm. Declared thermal resistance for Type L dry 037 (m2K/W): 2.15 (80 mm), 2.70 (100), 3.20 (120), 3.75 (140), 4.30 (160), 4.85 (180), 5.40 (200), 5.90 (220), 6.45 (240), 7.00 (260), 7.65 (280), 8.10 (300); Type M dry 1.50 (60) to 5.00 (200); Type H dry 0.90 (40) and 1.35 (60). Compression strength at least 50 kPa; tensile strength perpendicular to face at least 10 kPa. Outdoor exposure 4 weeks; specific heat capacity 2100 J/(kgK); biogenic carbon approximately 183 kg CO2eq/m3. Fire class (RTF) according to EN 13501-1: E.

  2. supplier figure RN-009TEM

    STEICO

    Rigid wood fibre sarking and sheathing board to EN 13171 and EN 14964, designation WF - EN 13171 - AFr100 - T5 - WS1,0 - MU5 - CS(10\Y)200 - DS(70,-)2 - TR30, EN-14964-IL. Declared thermal conductivity 0.048 W/(mK). Density 270 kg/m3. Water vapour diffusion resistance factor mu 5; sd 0.11 m at 22 mm, 0.18 m at 35 mm, 0.30 m at 60 mm. Declared thermal resistance 0.45 (22 mm), 0.70 (35 mm), 1.25 (60 mm) m2K/W. Compressive strength at 10% compression 0.20 N/mm2, that is greater than or equal to 200 kPa; tensile strength perpendicular to face greater than or equal to 30 kPa. Short term water absorption less than or equal to 1.0 kg/m2, outdoor exposure 4 weeks, suitable from a roof pitch of 14 degrees or more. Specific heat capacity 2100 J/(kgK). Fire class (RTF) according to EN 13501-1: E.

  3. supplier figure RN-HG2CBY

    Superglass (Etex)

    Non combustible glass mineral wool roll supplied 1200 mm wide to suit common rail and bracket systems. Declared thermal conductivity (lambda) 0.032 W/mK. Fire classification Euroclass A1 when tested to EN 13501-1:2018 Reaction to Fire. CCPI Assessment Mark certificate 005800128/0227. For walls and roofs of twin skin profiled metal clad systems and portable and modular buildings.

  4. supplier figure RN-46NYD5

    Unilin Insulation (formerly Xtratherm)

    Non combustible stone wool slab for ventilated facade, rainscreen, framing and curtain walling, 1200 x 600 mm, thicknesses 50, 75, 100, 120, 150, 180 and 200 mm. Thermal conductivity 0.036 W/mK. Reaction to fire: Euroclass A1. Published R-values (m2K/W): 50 mm 1.35, 75 mm 2.05, 100 mm 2.75, 120 mm 3.45, 150 mm 4.15, 180 mm 5.00, 200 mm 5.55.

  5. supplier figure RN-C4UZFY

    Zinsser UK

    Manufacturer data for a water based all surface exterior paint. Coverage is 12 m2 per litre and it is recoatable in 1 hour. It is designed for long term decoration of timber, metal, masonry, plastic, concrete and cladding, forming a vapour permeable water shedding coating, which is the property that matters on a solid wall that needs to breathe. The matt finish will bridge gaps in the painted surface up to 0.5mm wide. Coloured finishes are stated not to darken when wet, unlike many other matt exterior paints. The dried film is a treated article containing the biocides 2-octyl-2H-isothiazol-3-one at 0.06 per cent, Diuron at 0.15 per cent and Zinc Pyrithione at 0.06 per cent by weight.