  1. supplier figure RN-BXFQVE

    Glazing Vision Ltd

    Glazing Vision Flushglaze fire rated rooflight: minimum upstand pitch 3 degrees, maximum 10 degrees, with at least 5 degrees recommended for standard units, so it is a flat-roof-only product unlike the standard Flushglaze which goes to 70 degrees. Structural integrity verified by finite element analysis and testing.

  2. supplier figure RN-F361VU

    Glazing Vision Ltd

    Glazing Vision Flushglaze Eaves rooflight, a fixed rooflight designed to run out to the edge of a flat roof: width 400mm to 2000mm.

  3. supplier figure RN-VN6FVL

    Glazing Vision Ltd

    Glazing Vision Flushglaze fixed rooflight. Span from 400mm to 8626mm and width 400mm to 8626mm. Minimum upstand pitch 3 degrees, maximum 70 degrees, with at least 5 degrees recommended for standard units (above 70 degrees a roof window is needed instead). Tested at 2000mm span x 2500mm width at 0 degrees pitch: air permeability EN 12207 Class 4 at +600 Pa, water tightness EN 12208 Class 9A at 600 Pa. Security Rating A requires an inner pane of at least 8.8mm PVB laminated glass (two 4mm panes with a 0.8mm PVB interlayer); Security Rating B requires at least 9.5mm ionomer laminated glass (two 4mm panes with a 1.5mm ionomer interlayer). Structural performance verified by finite element analysis and testing.

  4. supplier figure RN-5BPXPN

    Glazing Vision Ltd

    Glazing Vision Flushglaze Multi-Part rooflight, which links panels for large openings: span 400mm to 4131mm. Minimum upstand pitch 3 degrees, maximum 70 degrees, at least 5 degrees recommended. Air permeability EN 12207 Class 4 at +600 Pa, water tightness EN 12208 Class 9A at 600 Pa. Tested to LPS 2081 Issue 1:2015, approved by the Loss Prevention Certification Board (Cert/LPCB reference 1347a) and Secured by Design.

  5. supplier figure RN-E1RXPB

    Glazing Vision Ltd

    Glazing Vision Flushglaze Walk On rooflight, toughened laminated glass designed for regular foot traffic in UK domestic use, tested to uniform loading of 1.5 kN/m2 and concentrated loading of 2.0 kN in accordance with EN 1991-1-1:2002. Span and width both 400mm to 8626mm. Minimum upstand pitch 1 degree (recommended pitch 1 degree for standard units), maximum 70 degrees. Tested at 2000 x 2500mm at 0 degrees: air permeability EN 12207 Class 4 at +600 Pa, water tightness EN 12208 Class 9A at 600 Pa. Security Rating A needs an inner pane of at least 8.8mm PVB laminated glass; Rating B needs at least 9.5mm ionomer laminated glass.

  6. supplier figure RN-58CW09

    Glazing Vision Ltd

    Glazing Vision Flushglaze Wall Abutted rooflight, designed to run up to and against a wall: span 400mm to 4131mm. Minimum upstand pitch 3 degrees, maximum 70 degrees, at least 5 degrees recommended for standard units. Security Rating A requires an inner pane of at least 8.8mm PVB laminated glass (two 4mm panes with a 0.8mm PVB interlayer); Rating B requires at least 9.5mm ionomer laminated glass (two 4mm panes with a 1.5mm ionomer interlayer).

  7. supplier figure RN-Z28L29

    Glazing Vision Ltd

    Glazing Vision free-standing SkyBox rooflight: span 1300mm to 3500mm, upstand pitch 0 degrees minimum and maximum. Tested to air permeability EN 12207 Class 2 at plus/minus 300 Pa, watertightness EN 12208 Class 7A at 300 Pa, and wind resistance EN 12210 Class C3 at +2400/-1200 Pa serviceability and +3200/-1250 Pa safety. Note these classes are lower than the flat Flushglaze range (Class 4 at 600 Pa, Class 9A at 600 Pa), which matters on exposed sites. Each unit is internally weather tested to BS EN 12207 before delivery.

  8. supplier figure RN-H8WZLL

    Glazing Vision Ltd

    Glazing Vision lantern rooflight: span 600mm to 1500mm, width 650mm to 2500mm. Minimum and maximum upstand pitch both 0 degrees, meaning the lantern sits on a level upstand and sheds water through its own pitched form rather than through a sloping kerb. Thermally broken framework, optional easy clean coating and trickle vents.

  9. supplier figure RN-T3Q9X3

    Glazing Vision Ltd

    Glazing Vision PitchRidge roof window, a ridge unit for pitched roofs: span 110mm to 4085mm on each side. Tested to air permeability EN 12207 Class 4 at plus/minus 750 Pa, watertightness EN 12208 Class E750 at 750 Pa, and wind resistance EN 12210 Class E2400 at plus/minus 2400 Pa serviceability and plus/minus 3600 Pa safety, the same higher-pressure regime as the other pitched roof windows in the range.

  10. supplier figure RN-9PQ8KE

    Glazing Vision Ltd

    Glazing Vision RidgeGlaze fixed rooflight, a two-sided ridge unit: span 500mm to 3000mm on each side. Minimum upstand pitch 10 degrees and maximum 50 degrees, a much steeper range than the flat Flushglaze products which run from 1-3 degrees. Security Rating A requires an inner pane of at least 8.8mm PVB laminated glass; Rating B requires at least 9.5mm ionomer laminated glass.

  11. supplier figure RN-Q4TIZY

    Glazing Vision Ltd

    Glazing Vision SkyHatch roof access rooflight. Manual version: span fixed at 1100mm minimum and maximum. Electric SkyHatch: span 800mm to 1500mm, width 800mm to 2000mm. Minimum upstand pitch 3 degrees, maximum 10 degrees, with at least 5 degrees recommended for standard units.

  12. supplier figure RN-HYH0BT

    Glazing Vision Ltd

    Glazing Vision Sliding Over Fixed rooflight: minimum span 1300mm, maximum span 3100mm; minimum width 1500mm, maximum width 5000mm. Minimum upstand pitch 3 degrees, maximum upstand pitch 30 degrees, with at least 5 degrees recommended for standard units. Thermally broken framework; optional easy clean coating and remote control. Structural integrity verified by finite element analysis and testing.

  13. supplier figure RN-FIHCBY

    Glazing Vision Ltd

    Glazing Vision Sliding Over Roof rooflight: span 1100mm to 3100mm. Minimum upstand pitch 3 degrees, maximum 30 degrees, at least 5 degrees recommended for standard units. Thermally broken framework with special colour options.

  14. supplier figure RN-O8IU5B

    Glazing Vision Ltd

    Glazing Vision Three Wall Box rooflight: span 1100mm to 2400mm. Minimum and maximum upstand pitch both 0 degrees, so it is designed for a level upstand only.

  15. supplier figure RN-1D8Z71

    Glazing Vision Ltd

    Glazing Vision VisionVent hinged opening rooflight, available in three operation variants with a thermally broken framework. Standard version: span 415mm to 2365mm, minimum upstand pitch 3 degrees, maximum 70 degrees, with at least 5 degrees recommended. Chain-operated VisionVent: span 808mm to 2365mm.

  16. supplier figure RN-9Q5MDN

    Glazing Vision Ltd

    Glazing Vision X-Vent AOV (automatic opening vent) rooflight for smoke ventilation: span fixed at 1400mm minimum and maximum. Minimum upstand pitch 3 degrees, maximum 5 degrees, with at least 5 degrees recommended, so it demands a nearly flat kerb. Security Rating A requires an inner pane of at least 8.8mm PVB laminated glass; Rating B requires at least 9.5mm ionomer laminated glass.

  17. supplier figure RN-M72NLM

    IKO PLC

    IKO Adesso torch-on capsheet for built-up felt roofs: supplied in 8m x 1m rolls (length 8000mm, width 1000mm) with a 75mm upper selvedge, in green or black mineral finish. Carries a Declaration of Performance, is UK Conformity Assessed and CE marked. Covered by a 10 year IKO material guarantee when installed and maintained as part of a built-up roof system in line with IKO literature, relevant Codes of Practice and UK Building Regulations.

  18. supplier figure RN-AJXT2I

    IKO PLC

    IKO Armourplan PSG PVC single ply roofing membrane: thickness 1.2mm, roll 20,000mm (20m) long by 2120mm wide. Adhered to most common substrates with IKO Spectrabond low foaming PU adhesive or IKOpro Sprayfast FMA adhesive. BBA Certificate 05/4287, CE marked.

  19. supplier figure RN-UGFZ49

    IKO PLC

    IKO Armourshield Plus hexagonal butt bitumen shingle: strip 1000mm long by 318mm wide, a bituminous pitched roofing product typically laid over a boarded deck with a glass fibre underlay.

  20. supplier figure RN-98IS5K

    IKO PLC

    IKO Challenger SBS torch-on capsheet, a merchant and DIY grade bituminous membrane: rolls 10,000mm (10m) long by 1000mm wide, covered by a 15 year IKO guarantee, between the 10 year Adesso and the 30 year Ultra Life 30 in the same range.

  21. supplier figure RN-PE31E7

    IKO PLC

    IKO Spectraplan SM, a polyester scrim-reinforced TPE (thermoplastic elastomer) membrane for mechanically fastened single ply roofing on flat and pitched roofs, and usable for ballasted and green roofs. Standard thickness 1.2mm, roll length 20,000mm (20m). The same polymer compound forms both faces and fully encapsulates the polyester reinforcement. BBA certificate 05/4203. Available in standard rolls or optional roll sizes between 200 m2 and 1,000 m2.

  22. supplier figure RN-1HMDQ0

    IKO PLC

    IKO Ultra Life 30 capsheet for built-up roofing: supplied in 8000mm (8m) rolls and covered by a 30 year IKO guarantee, against the 10 year guarantee on the standard Adesso torch-on capsheet in the same range.

  23. supplier figure RN-CM0KUW

    Kingspan Insulation

    Vacuum insulation panel system for flat roofs and terraces. Thermal conductivity 0.007 W/mK, declared to BS EN 12667: 2001 with allowance for ageing and the edge effect of the encapsulating film. Panels 300 x 300 mm, available in thicknesses of 20 to 50 mm. Declared compressive stress 150 kPa at 10% compression to BS EN 826: 2013. Fire: Euroclass rating of F; roofing system fire performance is normally evaluated by testing the whole system to DD CEN/TS 1187: 2012, and roofs fully covered by loose laid gravel at least 50 mm thick or at least 80 kg/m2 (aggregate 4 to 32 mm) are deemed to satisfy external fire performance without testing.

  24. supplier figure RN-AU8U24

    Kingspan Insulation

    Fibre-free rigid thermoset polyisocyanurate (PIR) board to BS EN 13165: 2012 + A2: 2016, foil faced both sides. Declared thermal conductivity 0.022 W/mK. Declared compressive stress 120 kPa at 10% compression to BS EN 826. Standard board 2400 x 1200 mm. BBA Certificate 14/5133 covers thicknesses 20 to 150 mm, made at Pembridge and Selby. Published R-values (m2K/W): 25 mm 1.10, 30 mm 1.35, 40 mm 1.80, 50 mm 2.25, 60 mm 2.70, 70 mm 3.15, 75 mm 3.40, 80 mm 3.60, 90 mm 4.05, 100 mm 4.50, 110 mm 5.00, 120 mm 5.45, 125 mm 5.65, 130 mm 5.90, 140 mm 6.35, 150 mm 6.80. Fire: under System 4 AVCP, TP10 has a Euroclass rating of F.

  25. supplier figure RN-WYINIS

    Kingspan Insulation

    Rigid thermoset polyisocyanurate flat roof board faced both sides with a low emissivity composite foil, 2400 x 1200 mm. Declared thermal conductivity 0.022 W/mK. Declared compressive stress 150 kPa at 10% compression to BS EN 826. Fire: under System 4 AVCP, TR26 has a Euroclass rating of F; the fire performance of a roofing system is determined by the finishes in combination with the insulation.

  26. supplier figure RN-681HZ7

    Kingspan Insulation

    Rigid thermoset polyisocyanurate flat roof board, coated glass tissue faced both sides, 1200 x 600 mm. Three declared lambda values by thickness: 0.027 W/mK below 80 mm, 0.025 W/mK for 80 to 119 mm, and 0.024 W/mK at 120 mm and above. Declared compressive stress 150 kPa at 10% compression to BS EN 826. Fire: under System 4 AVCP, TR27 has a Euroclass rating of F; roof system fire performance is normally evaluated by testing the whole system to CEN/TS 1187: 2012.

  27. supplier figure RN-A1M5LJ

    Klober Ltd

    Three layer air open roof underlay of UK stabilised PP fleece with a meltblown layer, dark blue. Weight 160 g/m2 to EN 1849-2. Water vapour transmission (SD value) EN 12572 0.009 m. Resistance to water penetration EN 1928 W1. Tensile strength MD/CD 280/200 N/50 mm to EN 12311-1; nail tear strength MD/CD 140/130 N to EN 12310-1; elongation MD/CD 50/70% . Fire rating EN 13501-1 EN 11925-2: E. Resistance to temperature -40 C to +80 C. BBA Certificate 07/4435 (cold non-vented and warm non-vented) and NHBC accepted without additional high level ventilation. Suitable for wind zones 1 to 3 with battened headlap and all wind zones with taped headlap at a 345 mm batten gauge.

  28. supplier figure RN-3NXM9O

    Klober Ltd

    Two layer underlay with a monolithic TPU coating on tear resistant PES fleece, dark blue. Weight 240 g/m2 to EN 1849-2. Water vapour transmission (SD value) EN 12572 0.08 m, so it is a high resistance membrane and requires ventilation. Resistance to water penetration EN 1928 W1. Tensile strength MD/CD 310/360 N/50 mm; nail tear strength MD/CD 215/200 N; elongation MD/CD 45/55%. Fire rating EN 13501-1 EN 11925-2: E. Temperature resistance -40 C to +80 C. Rated for minimum roof pitch 12.5 degrees for interlocking tiles, 15 degrees for slates and 22.5 degrees for plain tiles, wind zones 1 to 5 at a 345 mm batten gauge, tested to 1 in 50 year storm conditions.

  29. supplier figure RN-LGNE7O

    Klober Ltd

    Four layer roof underlay with polypropylene outer layers, a microporous polyethylene film inner layer and a reinforcement mesh safety grid, grey. Weight 145 g/m2 to EN 1849-2. Water vapour transmission (SD value) EN 12572 0.03 m. Resistance to water penetration EN 1928 W1. Tensile strength MD/CD 430/370 N/50 mm; nail tear strength MD/CD 320/340 N; elongation MD/CD 20/15%. Fire rating EN 13501-1 EN 11925-2: E. Temperature resistance -40 C to +80 C. BBA Certificate Numbers 00/3749 and 99/3622 (cold vented, warm non vented and cold non vented), NSAI approved. Wind zones 1 to 4 with battened headlap and all wind zones with taped headlap at a 345 mm batten gauge.

  30. supplier figure RN-HJDFIE

    Knauf Insulation

    Glass mineral wool multi purpose roll for timber and steel frame construction, partially perforated, made with ECOSE Technology. Declared thermal conductivity 0.040 W/(mK). Reaction to fire A1 to EN 13501-1. Supplied 570 mm wide: 100 mm x 6,800 mm giving R 2.25 (m2K)/W and 8.16 m2 per roll; 150 mm x 4,550 mm giving R 3.75 and 5.46 m2; 200 mm x 3,400 mm giving R 5.00 and 4.08 m2.

  31. supplier figure RN-SC0GWG

    Korniche (Made For Trade Ltd)

    Korniche aluminium roof lantern, fixed 25 degree pitch. Smallest size 850 x 850mm; bespoke sizes up to 6m x 4m external. Largest rectangular lantern using only 4 glass units 3m x 2.5m external; largest pyramid using only 4 units 2.5m x 2.5m; largest pyramid overall 4m x 4m. All double glazed units are 28mm, argon filled, with a warm edge spacer bar. A high strength polymer insulation core runs through the whole structure as a true thermal break, with thermally isolated fasteners. PAS 24 high security as standard.

  32. supplier figure RN-NAR50C

    Lawsons (Whetstone) Ltd

    the retail price Lawsons (Whetstone) Ltd publishes for Damp Proof Membrane DPM, which is the supply figure the cost book records for this item

  33. supplier figure RN-Z7MJSG

    Lawsons (Whetstone) Ltd

    the retail price Lawsons (Whetstone) Ltd publishes for Roofing Felts, which is the supply figure the cost book records for this item

  34. supplier figure RN-7OIF8R

    Lawsons (Whetstone) Ltd

    the retail price Lawsons (Whetstone) Ltd publishes for Roofing Lead, which is the supply figure the cost book records for this item

  35. supplier figure RN-CHO4HW

    Mannok (formerly Quinn Building Products)

    Foil faced rigid PIR roof board, 2400 x 1200 mm, thicknesses 20 mm to 200 mm. Thermal conductivity (lambda) 0.022 W/mK. Core water vapour resistivity approximately 300 MNs/gm. Compressive strength greater than 140 kPa. Certified under BBA certificate 07/4444 and IAB certificate 05/0223. Listed applications cover above rafters, above and between rafters, between and below rafters, at ceiling level, loft or attic walls, and cold deck flat roofs. The page does not state a Euroclass reaction to fire classification.

  36. supplier figure RN-XVF0CX

    Marley Alutec

    Marley Alutec Evolve aluminium rainwater product selector, flow rates from physical tests to BS EN 12056-3, maximum roof area quoted per downpipe. Half Round 120mm with 63mm round downpipe: 1.8 l/s, 87 m2. Deepflow 125mm with traditional or flush-fit 76mm round downpipe: 4.9 l/s, 232 m2. Box 130 x 85mm: 6.0 l/s and 286 m2 with a 76mm round downpipe, rising to 7.0 l/s and 333 m2 with a 72 x 72mm square downpipe. Ogee 130 x 95mm: same, 6.0 l/s / 286 m2 with 76mm round and 7.0 l/s / 333 m2 with 72 x 72mm square. Aluminium is stated as over 65% lighter than cast iron with a life expectancy of 50 years or more, and the brochure notes flow capacity improves marginally when the gutter is laid to a 1:600 fall. 24 standard colours including Heritage Black.

  37. supplier figure RN-0H8KU0

    Marley Ltd

    Marley 25mm Eaves Vent System: provides a continuous free vent area of either 10mm or 25mm to the roof void, giving 25,000 mm2 of free ventilation area per linear metre in the 25mm setting. Suitable for roof pitches from 12.5 to 55 degrees, and for both eaves-to-ridge and eaves-to-eaves ventilation, and can also ventilate the batten cavity. Allows clip fixing of all eaves tiles, compresses insulation to maintain airflow, prevents ponding on the underlay and blocks wildlife. Meets BS 5534 requirements and NHBC guidelines.

  38. supplier figure RN-VW44OH

    Marley Ltd

    Marley Anglia concrete single pantile: 387mm x 229mm, cover width 204mm nominal, hanging length 370mm. Minimum pitch 30 degrees smooth or granular at 75mm headlap, 25 degrees smooth at 100mm headlap; maximum 90 degrees. Minimum headlap 75mm, maximum gauge 312mm. Covering capacity 15.7 tiles/m2 at 75mm headlap, 17.1 at 100mm. Weight of tiling 47kg/m2 (0.46 kN/m2) at 75mm headlap, 51kg/m2 (0.50 kN/m2) at 100mm headlap. Battens 3.2 lin.m/m2 at 75mm, 3.5 at 100mm. Tile nails 38mm x 3.35mm.

  39. supplier figure RN-05CNNQ

    Marley Ltd

    Marley Canterbury handmade clay plain tile: 265mm x 165mm, cover width 165mm nominal. Minimum pitch 40 degrees (higher than the 30 degrees of the machine-made Acme plain tile), maximum 90 degrees. Minimum headlap 65mm roof, 35mm vertical; maximum gauge 100mm roof, 115mm vertical. Covering capacity 60 tiles/m2 at 100mm gauge roof, 53 tiles/m2 at 115mm gauge vertical. Weight of tiling 74 kg/m2 (0.73 kN/m2) at 100mm gauge roof, 66 kg/m2 (0.64 kN/m2) vertical, appreciably heavier than machine-made plain tile. Battens 10.0 lin.m/m2 at 100mm gauge, 38 x 25mm to 600mm centres fixed to BS 5534. Tile nails 38mm x 2.65mm.

  40. supplier figure RN-O8H8SR

    Marley Ltd

    Marley Double Roman concrete interlocking tile: 420mm x 330mm, cover width 300mm nominal, hanging length 397mm. Minimum pitch 25 degrees smooth at 75mm headlap, 30 degrees granular at 75mm headlap, 22.5 degrees smooth at 100mm headlap; maximum pitch 90 degrees. Minimum headlap 75mm, maximum gauge 345mm. Covering capacity 9.7 tiles/m2 at 75mm headlap, 10.4 at 100mm. Weight of tiling 44kg/m2 (0.43 kN/m2) at 75mm headlap, 47kg/m2 (0.46 kN/m2) at 100mm headlap. Battens 2.9 lin.m/m2 at 75mm headlap, 3.1 at 100mm. Tile nails 65mm x 3.35mm.