- supplier figure RN-SHAFKU
Cedral (Etex)
Flat fibre cement facade board, thickness 9 mm, available 2500 x 200 mm, 2500 x 300 mm, 2500 x 400 mm, 2500 x 1220 mm and 3050 x 1220 mm. Weight ranges from 6.5 to 47.4 kg per board depending on size. Fire safety classification A2-s1, d0 to EN 13501-1:2018. CCPI assessed.
- supplier figure RN-W38ETW
Cedral (Etex)
Fibre cement cladding board with a concealed click fixing. Length 3600 mm, width 186 mm, thickness 12 mm, weight 12.20 kg per siding, 1.60 sidings per m2 of facade. Fire safety classification A2-s1, d0 to EN 13501-1:2018. Can be placed horizontally or vertically, needs no painting, CCPI assessed.
- supplier figure RN-FIXXLV
Cedral (Etex)
Fibre cement weatherboard. Length 3600 mm, width 190 mm, thickness 10 mm, weight 11.20 kg per siding, 1.74 sidings per m2 of facade. Fire safety classification A2-s1, d0 to EN 13501-1:2018. Available in 22 colours with woodgrain or smooth finish, can be fitted horizontally or vertically, CCPI assessed. Covered by Cedral BBA certificates.
- supplier figure RN-M382W2
Delta Membrane Systems
HDPE cavity drain membrane. Stud height 20 mm, sheet thickness 1 mm, roll size 2.0 m x 20 m. Compressive strength 150 kN/m2. Drainage capacity 10 litres per second per metre, equal to 600 litres/min/m or 36,100 litres/hour/m, and 1.25 litres/second/m2. Air volume between studs 14 litres/m2. R value 0.18 m2K/W. Temperature resistance -30 C to +80 C. Reaction to fire Class E to EN 13501-1. The 20 mm stud gives roughly four times the drainage rate of the 8 mm product at the cost of depth taken off the room.
- supplier figure RN-982ZU5
Delta Membrane Systems
HDPE cavity drain membrane with DELTASAFE additive. Stud height 8 mm, sheet thickness 0.5 mm, roll size 2.4 m x 20 m. Compressive strength greater than 250 kN/m2. Drainage capacity 2.25 litres per second per metre, equal to 135 litres/min/m or 8,100 litres/hour/m. Air volume between studs 5.3 litres/m2. R value 0.12 m2K/W. Temperature resistance -30 C to +80 C. Reaction to fire EN 13501-1:2018 Class B-s2,d0, which is a higher fire classification than the Class E typical of plain HDPE cavity drain membranes.
- supplier figure RN-8ER1JE
EcoTherm Insulation (Kingspan Insulation Ltd)
Full fill cavity board, thermal conductivity 0.022 W/mK, standard thicknesses 90, 115 and 140 mm, BBA Certificate No 24/7114. Published R-values and typical U-values (with a 10 mm clear residual cavity and skim coated plasterboard on dabs internally): 90 mm R 4.05, U 0.18 brick and light block, 0.19 brick and medium block, 0.20 brick and dense block; 115 mm R 5.20, U 0.15 to 0.16; 140 mm R 6.35, U 0.13 to 0.14 W/m2K. Calculations use lambda values brick 0.77, dense block 1.13, medium block 0.51, lightweight block 0.11 W/mK. Fire: Eco-Cavity Full Fill has a Euroclass rating of F.
- supplier figure RN-O4K9TR
EcoTherm Insulation (Kingspan Insulation Ltd)
Partial fill cavity board, thermal conductivity 0.022 W/mK, declared compressive stress 120 kPa at 10% compression, thicknesses 50 to 100 mm, BBA Certificate No 24/7114. Published R-values and typical wall U-values with a 50 mm residual cavity: 50 mm board R 2.25, U 0.28 brick and dense block down to 0.24 light block and dense block; 60 mm R 2.70, U 0.25 to 0.21; 70 mm R 3.15, U 0.22 to 0.19; 75 mm R 3.40, U 0.21 to 0.19; 80 mm R 3.60, U 0.20 to 0.18; 100 mm R 4.50, U 0.17 to 0.15 W/m2K. Fire: Eco-Cavity has a Euroclass rating of F.
- supplier figure RN-P8XZXG
EcoTherm Insulation (Kingspan Insulation Ltd)
General purpose foil faced rigid PIR board to BS EN 13165: 2012 + A2: 2016. Thermal conductivity 0.022 W/mK. Declared compressive stress 120 kPa at 10% compression to BS EN 826. Manufactured range 25 to 150 mm, covered by BBA Certificate No 24/7114, made at Pembridge and Selby. Published R-values (m2K/W) with board weights: 25 mm 1.10 (3.38 kg), 30 mm 1.35, 40 mm 1.80, 50 mm 2.25 (5.62 kg), 60 mm 2.70, 70 mm 3.15, 75 mm 3.40, 80 mm 3.60, 90 mm 4.05, 100 mm 4.50 (10.08 kg), 110 mm 5.00, 120 mm 5.45, 125 mm 5.65, 130 mm 5.90, 140 mm 6.35, 150 mm 6.80 (14.54 kg). Maximum board span 600 mm when fixed to timber framing, metal channels, rafters or battens. Fire: Eco-Versal has a Euroclass rating of F.
- supplier figure RN-L2BGAW
fermacell (James Hardie Europe)
Manufacturer technical properties for fermacell gypsum fibreboard, a homogeneous gypsum and recycled paper fibre board with no separate paper liner. Thicknesses are 10, 12.5, 15 and 18mm weighing 11.5, 14.5, 17.5 and 21 kg/m2, so 12.5mm fermacell at 14.5 kg/m2 is nearly twice the 8.0 kg/m2 of standard 12.5mm plasterboard. Density is 1150 plus or minus 50 kg/m3. Thermal conductivity (lambda) is 0.32 W/mK. Expansion or contraction from a 30 per cent change in relative humidity at 20C is 0.25 mm per metre, the figure that governs joint detailing on long runs. Reaction to fire is classified to DIN EN 13501-1 and thickness swelling after 24 hours soaking in water is quoted, which is why it is used in wet areas and on floors. The high density is the reason it holds direct fixings and resists impact where plasterboard would not.
- supplier figure RN-7USMPB
fischer
High performance styrene free hybrid injection mortar in a shuttle cartridge, grey. Temperature resistance 120 C, UV resistant, water resistant with water absorption of 0.8% after 14 days, unaffected by a 1% tenside cleaning solution, and approved for outside use for freeze-thaw resistance under EOTA part 5. Shrinkage less than 0.9%. Shore A hardness 83 after 45 minutes. Density 1.6-1.8 g/cm3. Thermal conductivity 0.73 W/mK. Contact resistance 1.8 x 10^12 ohm cm. Viscosity at 20 C 110-150 Pas (Brookfield Sp.7 at 10 rpm). Open time at 10-20 C is 5 minutes and curing time at 10-20 C is 60 minutes. Shelf life 18 months. Cartridge temperature must be at least +5 C at installation.
- supplier figure RN-UJ805R
Forterra
Thermalite Hi-Strength 7 Block. Compressive strength 7.3 N/mm2, design thermal conductivity (protected, 3%) 0.185 W/mK, dry density 730 kg/m3, face size 440 x 215 mm. Forterra position it for homes above 2.5 storeys and room-in-roof construction. Reaction to fire class A1, sound reduction 41-50 dB depending on block thickness. Manufactured to BS EN 771-4, compliant with Masonry Wall Robust Details and supporting Approved Documents A, B, E and L.
- supplier figure RN-MHQJAX
Forterra
Thermalite Hi-Strength 7 Trenchblock, tongue and groove with integrated hand holds. Compressive strength 7.3 N/mm2, lambda below ground 0.29 W/mK, dry density 730 kg/m3, face dimensions 440 x 215 mm and 440 x 140 mm. Classified DS1-4 for resistance to ground contamination, so usable across a wide range of ground conditions. All 140 mm high trenchblocks are supplied flat-ended, without hand holds or tongue and groove. Manufactured to BS EN 771-4.
- supplier figure RN-O7W31K
Forterra
Thermalite Party Wall block. Design lambda 0.16 W/mK, dry density 660 kg/m3, face size 440 x 215 mm. Weights quoted at a typical as-received moisture content of 23% with moisture equilibrium about 3% protected and 5% exposed. Intended for separating walls between dwellings where Robust Details apply.
- supplier figure RN-J2DJG9
Forterra
Thermalite Shield Block 3.6. Compressive strength 3.6 N/mm2, design lambda 0.15 W/mK, dry density 600 kg/m3, face size 440 x 215 mm, height 215 mm, length 440 mm. Widths and weights: 50 mm 3.8 kg, 75 mm 5.7 kg, 100 mm 7.6 kg, 140 mm 10.6 kg, 150 mm 11.3 kg, 200 mm 15.1 kg, 215 mm 16.3 kg. Weights are quoted at a typical as-received moisture content of 23%, with moisture equilibrium about 3% protected and 5% exposed. Used for external walls, foundations, partitions and separating walls.
- supplier figure RN-J40OKU
Forterra
Thermalite Trenchblock 3.6 tongue and groove for below-ground construction. Compressive strength 3.6 N/mm2, lambda below ground 0.24 W/mK, dry density 600 kg/m3, height 215 mm, length 440 mm, widths 255 mm and 300 mm. Note the below-ground lambda is quoted separately from the 0.15 W/mK design value used above DPC for the equivalent 3.6 N/mm2 block.
- supplier figure RN-QBJ450
Forterra
Thermalite Turbo Block 2.9. Compressive strength 2.9 N/mm2, design lambda 0.11 W/mK, dry density 470 kg/m3, face size 440 x 215 mm. Widths and weights: 100 mm 6.1 kg, 140 mm 8.5 kg, 150 mm 9.1 kg, 190 mm 11.5 kg, 200 mm 12.1 kg, 215 mm 13 kg. Weights based on block gross density plus 50 kg/m3 at a typical as-received moisture content of 23%. This is the lowest lambda block in the standard Thermalite wall range.
- supplier figure RN-GXIJ3G
Forterra (Ecostock)
Ardleigh Yellow Stock, an Ecostock soft mud brick from the Measham factory. Manufactured to BS EN 771-1. Dimensions 215 x 102.5 x 65 mm. Compressive strength 30 N/mm2, configuration frogged with 2-12% voids, dry weight 2.36 kg. Durability rating F2, active soluble salts S2, water absorption 13%. Thermal conductivity lambda 10,dry 0.54 W/mK, and 0.9 W/mK exposed at 5%. Dimensional tolerance mean T2, range R1. Texture stock thrown.
- supplier figure RN-3CNLHI
Glidevale Protect (Building Product Design Ltd)
Vapour permeable wall membrane to BS EN 13859-2:2010, weight 100 g/m2 to BS EN 1849-2. Roll sizes 0.54 m x 100 m (54 m2, 5.4 kg) and 1.35 m x 100 m (135 m2, 14 kg). Water vapour resistance to BS EN ISO 12572 0.03 MNs/g, 0.005 Sd. Resistance to water penetration to BS EN 13111 Pass, Class W2, no leakage aged. Nail tear strength to BS EN 12310-1 modified MD 230 N, CD 245 N. Unaged tensile strength to BS EN 12311-1 modified MD 220, CD 225 N/50 mm; aged MD 185, CD 187 N/50 mm. Flexibility at low temperature to BS EN 1109 -40 C. Ageing conditions: UVA lamps at 50 C for 336 hours then heat ageing at 70 C for 90 days.
- supplier figure RN-YE9Z0D
Glidevale Protect (Building Product Design Ltd)
Declaration of Performance for Protect TF200 vapour permeable wall underlay, AVCP System 3, tested by notified laboratory 1301 TSUS Bratislava to EN 13859-1 & 2: 2010/2014. Weight 100 (-4) gsm. Water resistance unaged W2, aged W2. Tensile strength unaged MD 225 (-35) N/50 mm, CD 200 (-35) N/50 mm; aged MD 150 (-40), CD 180 (-30). Elongation unaged 80 (+20)% both directions, aged 40 (-10)%. Tear resistance 130 (-50) N both directions. Flexibility at low temperature -40 C. Water vapour resistance unaged less than or equal to 0.02 MNs/g, less than or equal to 0.003 sd (m). Resistance to water penetration greater than 25 cm to EN ISO 20811. Reaction to Fire: NPD, Class F.
- supplier figure RN-ABFSB5
H+H UK
Celcon Foundation Blocks for below ground work. Two strengths, 3.6 N/mm2 and 7.3 N/mm2, at densities 600 kg/m3 and 730 kg/m3. Thermal conductivity below ground is quoted separately as 0.24 W/mK and 0.29 W/mK, and H+H note explicitly that these figures differ from the above-DPC values because moisture content below ground is higher. A single foundation block replaces two skins of blockwork below DPC.
- supplier figure RN-HU3368
H+H UK
Celcon High Strength Grade aircrete block. Compressive strength 7.3 N/mm2, thermal conductivity 0.18 W/mK, dry density 730 kg/m3, widths 100 mm to 355 mm. Covered for beam and block floor infill by BBA certificate 05/4275, which applies to all Celcon grades.
- supplier figure RN-1JABK3
H+H UK
Celcon Jumbo Bloks, code SK. Available at compressive strengths 2.9, 3.6, 7.3 and 9.7 N/mm2 with thermal conductivities 0.11, 0.15 and 0.18 W/mK, density from 460 kg/m3. The 9.7 N/mm2 option is the highest strength in the Celcon aircrete range.
- supplier figure RN-MA7VQU
H+H UK
Celcon Plus Blocks, the large format thin-joint range. Available at compressive strengths 2.9, 3.6, 7.3 and 8.7 N/mm2 with matching thermal conductivities 0.11, 0.15 and 0.18 W/mK, from a density of 400 kg/m3. Laid with Celfix thin layer mortar rather than a conventional 10 mm bed.
- supplier figure RN-5V98H2
H+H UK
Celcon Solar Grade aircrete block. Compressive strength 2.9 N/mm2, thermal conductivity 0.11 W/mK, dry density 460 kg/m3. This is the lowest lambda block in the Celcon range and is the one specified where the inner leaf has to carry the U-value. Page links the Solar Grade 2023 datasheet, the Celcon Blocks 2023 datasheet and pack information.
- supplier figure RN-5KTFKZ
H+H UK
Celcon Standard Grade aircrete block, product code S. Compressive strength 3.6 N/mm2, thermal conductivity 0.15 W/mK, dry density 600 kg/m3. UKCA marked with separate certificates by product and thickness, including SCP100, SCP140, SCP150, SRC075, SRC100, SRC140, SRC150 and SRC215, so the range runs from a 75 mm to a 215 mm block. Supporting technical data sheets on the page cover fire resistance (TSD01), masonry movement (TSD02), characteristic strength of masonry (TSD03), U-values (TSD04, July 2026), fixings (TSD20), block weights (TSD43), external render (TSD45), sound and Robust Details (TSD57) and mortar yields (TSD62). BBA certificate 01/3816 Sheet 1.
- supplier figure RN-2JM9A9
H+H UK
Celcon Super Strength Grade aircrete block. Compressive strength 8.7 N/mm2, thermal conductivity 0.18 W/mK, dry density 730 kg/m3. Same lambda and density as High Strength Grade but 1.4 N/mm2 more compressive strength, which is the reason to specify it. BBA certificate 05/4275 for beam and block floor infill.
- supplier figure RN-9RFNFX
Helifix (Leviat)
BowTie is a long stainless steel tie that stabilises bulging walls by securing them into the ends of internal floor joists, with no external pattress plates. The BowTie HD is a heavy duty 12 mm diameter threaded bar with a self-cutting end, used where the wall must be tied back to internal floor joists or roof beams running parallel to it. Self-tapping so timbers do not split, suitable for hardwood, and installed from outside. Kit components: clearance-hole drill bit, BowTies, power support tool, HD Driver, hand support tool, and PolyPlus resin cartridge with extension nozzles and applicator.
- supplier figure RN-VQLRYT
Helifix (Leviat)
Kit contents: 10 x 1 m lengths of 6 mm HeliBar, one 3 litre tub of HeliBond cementitious grout, mortar chisel and rake, mixing paddle, and an applicator with nozzle. A 3-jaw-chuck power drill is needed but not supplied. Dimensions that matter: slots are cut into the horizontal mortar beds a minimum of 500 mm either side of the crack, and are 10 mm wide as standard to take the 6 mm HeliBar, with 4.5 mm HeliBar used for thin joints. Where two or more cracks are close together one continuous bar is used, long enough to extend 500 mm beyond the outer cracks, so three cracks at 250 mm apart need a 1.5 m bar. Slots are prepared with HeliPrimer WB or thoroughly wetted, HeliBond is the recommended bonding agent, and PolyPlus resin is used for small jobs or where load is applied quickly. Suitable for listed and historic structures and lime mortar.
- supplier figure RN-EGCKI9
Helifix (Leviat)
DryFix is a one-piece grade 316 stainless steel tie driven in with an SDS hammer drill and a Power Driver Attachment, needing no resin, grout or mechanical expansion. It works in brick, block, concrete, hard mortar and timber, in cavity and solid walls, hollow materials and close to edges, and the installed tie sits recessed below the face of the masonry. Multiple drip points stop water crossing the cavity, and it can be driven through insulation without affecting thermal performance. System components are the DryFix tie, RP drill bits for pilot holes, the Power Driver Attachment and extension, and a Load Test Unit with Pull Test Key. Variants: DryFix Terracotta for delicate terracotta, DryFix RenderPin for loose render and DryFix Asymmetric for a soft outer leaf on a hard inner leaf.
- supplier figure RN-AW2DTD
Helifix (Leviat)
HeliBar is austenitic stainless steel helical reinforcing bar. It starts as round wire with a typical 0.2% proof stress of 500 N/mm2; the cold forming process that creates the helical hi-fin profile more than doubles that to around 1100 N/mm2. Bars are bonded into cut slots with HeliBond thixotropic cementitious grout, the composite action being the basis of the Helibeam System. Short 1 m lengths are used singly for crack stitching; longer lengths are used in pairs to form masonry beams that redistribute loads from foundation movement, and to create or reinstate failed lintels. Using 400 mm bars bonded at one end only, with the free end in a bonded sleeve, forms a movement joint. Applications listed include crack stitching, lintel repair, deep masonry beams, horizontal restraint with BowTie, reconnecting separated walls, securing parapets and supporting masonry over new openings.
- supplier figure RN-GXC3WT
Ibstock
Ibstock code A0270A, Aldridge Multi Rustic, wirecut extruded with a rusticated face, made at Aldridge. Dimensions 215 x 102 x 65 mm, size tolerance T2 R1, vertically perforated with 27-32% voids. Compressive strength 25 N/mm2, active soluble salts S2, water absorption 12% by weight, durability F2. Gross dry density 1470 kg/m3, equivalent thermal conductivity K value at 5% exposed 1.09 W/mK, initial rate of absorption (suction rate) 0.7 kg/m2/min. Dry brick weight 2 kg, pack quantity 500.
- supplier figure RN-NGY0UA
Ibstock
Ibstock code A4057A, Ashdown Medium Multi. Dimensions 215 x 102 x 65 mm, size tolerance T1 R1, single frog with 10-15% voids. Compressive strength 30 N/mm2, active soluble salts S2, water absorption 15% by weight, durability F2. Gross dry density 1610 kg/m3, equivalent thermal conductivity K value at 5% exposed 0.86 W/mK, initial rate of absorption 1.9 kg/m2/min, which is high enough that the brick will need wetting or a water-retentive mortar in warm weather.
- supplier figure RN-MMH1NP
Ibstock
Ibstock code A0129A, Aston Burnt Red. Dimensions 215 x 102 x 65 mm, tolerance T2 R1, vertically perforated with 33-38% voids, the highest void ratio of the Ibstock bricks listed here. Compressive strength 25 N/mm2, active soluble salts S2, water absorption 12%, durability F2. Gross dry density 1600 kg/m3, equivalent thermal conductivity K value at 5% exposed 1.16 W/mK, initial rate of absorption 0.3 kg/m2/min.
- supplier figure RN-DI0GDB
Ibstock
Ibstock code A2601A, Beamish Blend. Dimensions 215 x 102 x 65 mm, tolerance Tm Rm, solid with 0% voids. Compressive strength 20 N/mm2, active soluble salts S2, water absorption 12% by weight, durability F2. Gross dry density 1740 kg/m3, equivalent thermal conductivity K value at 5% exposed 0.86 W/mK, initial rate of absorption 0.6 kg/m2/min. A solid, no-void brick, which matters where the brick is cut or exposed on edge.
- supplier figure RN-CZED6F
IG Lintels (Keystone Group)
HDBOX 100, SKU HDBOX/K100, heavy duty closed box lintel used to support openings in 100 mm wide internal walls, wall depth 100-140 mm. Total UDL by length: 600-1200 mm, 150 mm high, 2.5 mm steel, 50 kN; 1350-1800 mm, 150 mm high, 2.5 mm, 45 kN; 1950-2400 mm, 215 mm high, 2.5 mm, 50 kN; 2550-2700 mm, 215 mm high, 2.5 mm, 40 kN. Sister sizes HDBOX 140 and HDBOX 200 cover wider walls.
- supplier figure RN-TDGR73
IG Lintels (Keystone Group)
HDBOX 140, SKU HDBOX/K150, heavy duty closed box lintel used to support openings in 150 mm wide walls, wall depth 100-140 mm. Total UDL by length: 600-1200 mm, 150 mm high, 2.5 mm steel, 50 kN; 1350-1800 mm, 150 mm high, 45 kN; 1950-2400 mm, 215 mm high, 50 kN; 2550-2700 mm, 215 mm high, 40 kN.
- supplier figure RN-3CE9B0
IG Lintels (Keystone Group)
HT/HD+ 100 Hi-therm heavy duty thermally broken lintel for 90-105 mm cavities. Total UDL at 3:1 and 19:1 load ratios by length band: 600-1500 mm, 144 mm high, 2.9 mm steel, 30 kN and 22 kN; 1650-2400 mm, 226 mm high, 2.9 mm, 35 kN and 35 kN; 2550-3000 mm, 226 mm high, 3.2 mm, 35 kN and 35 kN; 3150-3600 mm, 215 mm high, 2.9 mm, 35 kN and 32 kN.
- supplier figure RN-ZB4A3Z
IG Lintels (Keystone Group)
INT 100, SKU INT/K-100, light internal lintel for solid walls. Overall length 900 mm gives a 700 mm maximum span at 7 kN total UDL; 1050 mm gives 850 mm at 7 kN; 1100 mm gives 900 mm at 7 kN; 1200 mm gives 1000 mm at 7 kN. IG state that one course of mortar must be allowed to cure for at least 24 hours before additional loads are applied, and that INT 100 is not suitable for floor loads. Specify INT 64 for a 75 mm solid wall.
- supplier figure RN-KFYJSE
IG Lintels (Keystone Group)
L1/HD 100 heavy duty lintel for 90-105 mm cavities, 102 mm outer leaf, 100 mm inner leaf. Total UDL by length band, quoted at 3:1 and 19:1 inner-to-outer load ratios: 600-1200 mm, 109 mm high, 2.9 mm steel, 30 kN and 22 kN; 1350-1500 mm, 136 mm high, 2.9 mm, 30 kN and 22 kN; 1650-2100 mm, 161 mm high, 2.9 mm, 40 kN and 35 kN; 2250-2550 mm, 199 mm high, 2.9 mm, 40 kN and 35 kN; 2700-3000 mm, 199 mm high, 3.2 mm, 40 kN and 35 kN.
- supplier figure RN-UQH4M2
IG Lintels (Keystone Group)
L1/S 100 standard load lintel for 90-105 mm cavities, 102 mm outer leaf, 100 mm inner leaf. Loading table by manufactured length: 600-1200 mm, 87 mm high, 1.6 mm steel, total UDL 12 kN at a 3:1 load ratio and 10 kN at 19:1; 1350-1500 mm, 87 mm high, 1.8 mm steel, 16 kN and 13 kN; 1650-1800 mm, 107 mm high, and so on up the range. Lengths are made in 150 mm increments.