Heating, Energy & Eco
274 sources in the library on heating, energy & eco. Each one says what the document covers and what it is good for. Name a source to see which document it is and where to read it. One at a time. Page 5 of 7.
- fair RN-B0M8W5
Citizens Advice
What it costs and takes to move a meter during building work. Moving the meter a short distance on the same wall is arranged with the energy supplier; moving it further, or moving the supply itself, has to go through the local electricity or gas network operator, which usually charges at least £400 and can charge over £1,000 depending on the work. Appointments are normally within working hours, meaning roughly 9am to 5pm, in a time slot of 2 to 4 hours. If the supplier misses the appointment or fails to give proper notice, it must pay £40 compensation within 10 working days, and a further £40 if that payment is late.
- fair RN-W3C1L8
CO-Gas Safety
Carbon monoxide risk figures from the charity. UK residents spend around 90% of their time indoors, and the most important avoidable indoor contaminants are the products of combustion. Less than 2% CO in air can kill or maim in between one and three minutes. Extrapolating from university research in 2006 and 2011, more than 3 million people are exposed to levels above 50 parts per million of CO in their UK homes, against a WHO 24 hour guideline of 6 ppm, and known deaths and injuries cost the UK taxpayer £178 million a year. States that a CO alarm must meet EN50291 and that such an alarm should not cost more than £20. Also sets out what to do after suspected exposure, including allowing the Gas Emergency Service to isolate appliances.
- fair RN-FUREBB
Energy Ombudsman
Confirms the Ombudsman can review disputes with electricity and gas network operators over loss of service, or a problem with a connection or a repair, which is the route for a renovation held up by a new or altered supply. Lists the electricity distribution network operators signed up to the scheme, including Eastern Power Networks, Electricity North West, London Power Networks, Northern Powergrid (Northeast), Northern Powergrid (Yorkshire), Scottish Hydro Electric Power Distribution, South Eastern Power Networks and Southern Electric Power Distribution. The operator has 8 weeks to resolve the issue unless it issues a deadlock letter allowing earlier escalation.
- fair RN-HUMCU5
Energy Ombudsman
The timetable of an energy dispute. The supplier gets 8 weeks to resolve a complaint; the consumer can escalate sooner only if a final decision or deadlock letter arrives. Escalation must happen within 12 months of the deadlock letter. Once registered, if Facilitated Complaints Resolution is not offered or not accepted, the consumer has up to 14 days to supply supporting evidence. A decision normally follows within 6 weeks, longer for complex cases. The Ombudsman decides on the evidence, the law, relevant regulation and accepted good industry practice, and a typical financial award ranges between £50 and £100. Once the consumer accepts, the decision is legally binding on the supplier, which has 28 days to implement the remedies, after which the consumer may pursue the matter in court. The service is free to the consumer. Advises recording complaint dates, call reference numbers and proof of posting.
- fair RN-VM0Y7O
Energy Saving Trust
Domestic battery storage sizing, cost and life. Capacity is measured in kilowatt hours and a typical home system is around 10 kWh. A typical unit measures about 100cm x 60cm x 25cm, slightly taller and wider than a washing machine but much less deep. Cost ranges from £1,500 to £10,000, with a 5 kWh system around £4,600. Typical lifespan is about 10 to 12 years, and the system stops discharging at a set floor, perhaps 20% of total capacity. Last updated 19 August 2026.
- fair RN-IRAQA2
Energy Saving Trust
How to identify and choose a domestic boiler. Heating and hot water account for over half of annual energy spend. A boiler is a condensing model if it is a gas or LPG boiler installed after 2005, or an oil boiler installed after 2007. On cylinders, upgrading hot water cylinder insulation to 80mm saves around £45 a year in Great Britain and £35 in Northern Ireland, and when replacing a cylinder it should be sized no larger than needed. Replacement costs quoted on the page are around £3,500 and £3,200 by system type. Notes solar water heating can supplement but never fully replace a boiler or immersion heater because sunlight varies through the year. Last updated 20 May 2026.
- fair RN-54KWR6
Energy Saving Trust
How to identify a cavity wall and what filling it costs. About 33% of all heat lost from an uninsulated home escapes through the walls. Houses built after the 1920s usually have cavity walls; pre 1920 houses are usually solid; houses from the 1990s onwards usually already have wall insulation. Identification: cavity walls show an even stretcher bond with all bricks laid lengthways, solid walls show an alternating pattern with header ends visible; a brick wall 260mm to 350mm thick is likely a cavity wall, narrower is likely solid, stone walls are solid up to about 500mm thick and earth walls run 300mm to over a metre. Typical installed cost around £2,200 in Great Britain and around £1,000 in Northern Ireland, with payback usually five years or less. Unsuitable where the wall is exposed to extreme weather or flooding, in poor condition, at risk of overheating, or where the cavity is narrower than 50mm. External repairs to brickwork, pointing, roofs, gutters and downpipes must be completed first or damp can be trapped. Underfloor grilles, airbricks, wall vents and trickle vents must not be blocked. Post installation damp is chased through the installer, then the Cavity Insulation Guarantee Agency guarantee or an independent insurance backed guarantee.
- fair RN-FRD5VY
Energy Saving Trust
Draught proofing costs and savings. Professional draught proofing of windows and doors across a whole house costs around £250, with DIY cheaper. A terracotta chimney pot cap starts at around £150 and also keeps out moisture and birds. Savings: around £55 a year in Great Britain and £80 in Northern Ireland from draught proofing windows, floors and doors, plus around £45 in GB and £60 in NI from draught proofing an unused open chimney. A draught free home is comfortable at a lower setting, and turning a thermostat down from 22 degrees C to 21 degrees C saves £120 a year in GB and £80 in NI. Warns that further draught proofing of an already well sealed home raises the risk of poor indoor air quality.
- fair RN-SS1KSR
Energy Saving Trust
Glazing performance, life and price. A set of A-rated windows for a semi detached house typically costs around £4,800. Replacing single glazing with A-rated double glazing across a semi detached house saves £85 a year in Great Britain and £140 in Northern Ireland, and cuts 290kg of CO2 a year in GB and 550kg in NI. Triple glazing costs around 20% more than double glazing, justified mainly in cold or noisy locations. Good quality, correctly installed and maintained double glazed units last 20 to 35 years and can go well beyond 35 years where the seals and gaskets are checked and the units kept clean and ventilated.
- fair RN-S02RP7
Energy Saving Trust
How to read and obtain an EPC. Certificates are valid for 10 years from the date of issue. Checkatrade pricing accurate as of November 2025 puts an EPC at £65 to £120. A property being sold or let must have one, and the fixed penalty charge for failing to provide one is £200. Walks through the certificate layout using a 2023 Scottish example, noting older certificates carry most of the same information in a different order. Last updated 8 May 2026.
- fair RN-3G2Z0L
Energy Saving Trust
Condensation control by the numbers. A household typically produces up to 100 litres of moisture a week, which builds on surfaces or stays in the air unless ventilated out. Run a bathroom extractor for at least 15 minutes after a shower or bath and a cooker extractor for at least 15 minutes after cooking, or where there is no fan open a window for the same period. Leave a gap of at least 10mm under internal doors, measured from the top of the floor covering to the bottom of the closed door, so air can move between rooms. Distinguishes condensation from rising and penetrating damp and sets out the order of works.
- fair RN-5QU93S
Energy Saving Trust
Practical domestic ventilation rules. Internal doors need a 10mm gap between the bottom of the door and the top of the carpet or flooring so air circulates. Extractor fans should be run, or a window left open, for around 15 minutes after showering, bathing or cooking. Trickle vents should be kept open all year round including in winter, and reopened promptly if they are ever shut to keep cold air out. Ventilation matters as much in winter as in summer.
- fair RN-INHUMS
Energy Saving Trust
Water use figures for a UK home. Ofwat puts average personal use at around 150 litres a day. A UK Government report puts hot water at around 18% of a household's heat demand. Swapping an inefficient shower head for a water efficient one saves a typical home £65 a year in Great Britain and £25 in Northern Ireland across combined heating and water bills. Consumer Council for Water figures put a running tap at around nine litres a minute, and it takes just 95 seconds of a typical running tap to use as much water as filling a washing up bowl. A dripping tap wastes thousands of litres a year, so washers should be changed promptly. Last updated 19 June 2026.
- fair RN-VL002T
Energy Saving Trust
Cheap heat loss fixes with the payback attached. A hot water cylinder jacket costs about £30 in Great Britain and £30 in Northern Ireland and is a straightforward DIY fit. An existing jacket should be at least 80mm thick, and adding an 80mm British Standard jacket over a tank with only 25mm of built in foam saves £45 a year in GB and £35 in NI, more than the jacket costs. Insulating exposed indoor hot water pipes saves around £6 a year in both GB and NI. Savings are stated on January 2024 fuel prices for a typical three bedroom semi detached house, gas heated in GB and oil heated in NI.
- fair RN-LYRGT5
Energy Saving Trust
The new plug in solar category, legal to use in Great Britain since 27 August 2026 where the device meets the relevant standards, with Northern Ireland pending regulation. UK compliant devices are capped at a maximum output of around 800W, which EST's research puts at around 700 kWh a year. A compliant system costs from around £450 installed, against around £7,600 for an average rooftop array. Savings are around £100 a year for a household at home all day and around £70 for one out during the day. The modelling assumptions are stated: an 800W system in Manchester, south facing at 30 degrees from horizontal with no shading, 2,500 kWh annual household electricity use, which is Ofgem's typical domestic consumption value, and electricity at 24.7p per kWh. Individual panels are typically 400 to 500W. Last updated 2 September 2026.
- fair RN-MQVKCT
Energy Saving Trust
A costed micro measure. Radiator foil panels cost around £25 for a roll from a DIY store, cut to size to fit snugly behind the radiator. Fitted to radiators on uninsulated external walls they save £18 a year in Great Britain or £20 in Northern Ireland, and cut carbon by 60kg a year in GB or 110kg in NI. Last updated 31 October 2025.
- fair RN-00VIDG
Energy Saving Trust
Solar thermal performance and cost. Hot water accounts for around 11% of the average energy bill. A typical installed system costs around £5,300. Output is seasonal: roughly 90% of hot water demand in summer falling to around 25% in winter, averaging about half of annual hot water needs, so the system is always paired with a conventional boiler or immersion heater. Installation by an MCS certified contractor brings both workmanship and product warranties, typically several years on workmanship and longer on the collectors themselves. Maintenance requires a thorough check every five years to flush the system and replace the fluid mix. Last updated 20 May 2026.
- fair RN-X0H4VV
Energy Saving Trust
Gives the installed rate for the two underfloor heating types: a dry electric system £50 to £85 per m2, and a wet water based system £85 to £110 per m2. Covers the trade off between them, the need for floor build up and insulation beneath, and suitability with a heat pump because of the low flow temperature. Last updated 2 October 2025.
- fair RN-Q7QAUV
HomeOwners Alliance
Costed menu of efficiency measures. EPC £60 to £120 by property size. Loft insulation about £900 for a three bedroom semi, £1,100 detached, £1,200 detached bungalow per Energy Saving Trust, needing between 12cm and 30cm of thickness in most homes. PVC windows about £4,250 for a typical semi, roughly £325 per window, against about £15,000 for hardwood, roughly £1,500 per timber sash, with double glazing saving around £95 a year and requiring a FENSA accredited installer because building regulations apply to any window replacement. Cavity wall insulation about £22 to £26 per m2 for polyurethane foam or £13 to £18 per m2 for glass wool, averaging £725 for a detached house and £370 for a mid terrace. Internal wall insulation about £7,500 for a three bedroom semi saving around £210 a year, at a cost of about 10cm of lost floor depth. External wall insulation around £100 per m2, from £8,000 for a small flat to £22,000 for a large detached house. Solid concrete floor insulation £950 to £2,200 per room; suspended timber floor insulation £300 to £750 per room, saving about £50 a year or up to £85 in a detached house. Air source heat pump £3,000 to £18,000, ground source £13,000 to £35,000. Solar panels £2,500 to £8,000, with OVO estimating a 3.5kW array in southern England returns around £300 in year one.
- fair RN-2R9FZY
Leeds Beckett University
Two new European Standards for measuring aggregate heat loss from housing were published in 2024 and adopted in 34 countries, led by Professor David Johnston at Leeds Beckett with Professor Richard Fitton at the University of Salford. The standards are built on the Coheating Test developed at Leeds Beckett and, crucially, apply to new and existing real homes rather than laboratory test cells, so the thermal performance of housing can be measured and compared consistently across countries. The work took a decade. This is the standardisation behind the EN 17887 series used by Salford's Energy House Labs.
- fair RN-WK9XK3
Leeds Beckett University, Centre for the Built Environment
Tests the industry rule of thumb that background infiltration equals the blower-door result divided by twenty (n50/20, or q50/20 in the UK). Background ventilation rates in four new-build UK dwellings were measured directly by tracer-gas decay and compared with the pressurisation method using the conventional divide-by-twenty rule and Sherman's modified rule which accounts for building-related factors. The conventional rule over-estimated the air change rate in two dwellings and under-estimated it in the other two; the modified rule matched in two and significantly under-estimated in the other two. The conclusion is that the rule of thumb can produce significant errors in estimating infiltration, which in turn corrupts predicted in-use energy and CO2 emissions and can lead to ventilation strategies giving either unacceptable indoor air quality or unnecessary energy use, and that appropriate UK climate and building correction factors have yet to be devised. Johnston and Stafford, Indoor and Built Environment, 2016.
- fair RN-1H6AUM
Leeds Beckett University, Leeds Sustainability Institute
88 side-by-side fan pressurisation and low-pressure pulse airtightness measurements in existing dwellings of differing age, size, form and construction. Results: across the sample the mean airtightness reported by the two methods differed by only 2 per cent, but for individual homes the difference ranged from minus 84 per cent to plus 67 per cent, so the two tests can give wildly different answers on any one house even though they agree on average. Regulatory context stated: UK Building Regulations set a maximum airtightness of 8 m3/m2/h at 50 Pa for new dwellings, reducing to 5 m3/m2/h at 50 Pa or less in 2025 with the Future Homes and Buildings Standard; compliance is demonstrated by fan pressurisation or the newer low-pressure pulse test as set out in CIBSE TM23:2022. There is no maximum airtightness requirement when refurbishing an existing dwelling, though both methods are being used to inform retrofit, and existing homes have more varied and complex leakage paths than new build.
- fair RN-Z9ZEG1
Leeds Beckett University, Leeds Sustainability Institute
Review of measured in-use indoor air quality in more than 600 Passive House or PH-like newly built or retrofitted dwellings (Rojas, Fletcher, Johnston and Siddall, Energy and Buildings 306, 2024). Findings: pollutant and CO2 concentrations are generally lower than in naturally ventilated homes, attributed to the required balanced MVHR system, and the quality assurance of PH certification measurably improves ventilation and IAQ performance. The paper adopts CO2 up to 1400 ppm as the indicator of acceptable ventilation from a health perspective, assuming low-emitting materials, and notes typical steady-state figures of 1350 to 1800 ppm for standard occupancy assumptions. Numbers a specifier can use: PH ventilation criteria require MVHR heat recovery efficiency above 75 per cent, specific fan power including controls below 0.45 Wh/m3, supply and extract air flows balanced to within 10 per cent, and internal leakage of the MVHR unit limited to under 3 per cent. Filter grade moved to ePM1(50 per cent) or better in November 2018. The named weakness of the standard is the lack of a cooking fume capture requirement, combined with efforts to avoid the energy losses of extraction.
- fair RN-Q0N9LY
Leeds Beckett University, Leeds Sustainability Institute
The research that changed Building Regulations on party walls. Leeds Sustainability Institute produced the empirical evidence that the cavity between party walls separating adjoining properties was responsible for a significant, previously unrecognised, heat loss, and that this bypass accounted for part of the discrepancy between predicted and measured heat loss in new dwellings. That heat loss mechanism is now formally recognised and developers must insulate walls between adjoining properties; previously heat could escape through and between party walls to the external environment. Context given: energy consumption in homes is responsible for around 15 per cent of UK carbon emissions. Underpinning paper: Lowe, Wingfield, Bell and Bell (2007), Evidence for heat losses via party wall cavities in masonry construction, Building Services Engineering Research and Technology 28(2), 161-181.
- fair RN-UYYMUJ
Leeds Beckett University, Leeds Sustainability Institute
37 pressurisation and co-pressurisation tests on attached UK homes, measuring how much of the measured leakage is actually air moving between neighbouring dwellings rather than to outside. On average 21 per cent of the air leakage measured by a fan pressurisation test was inter-dwelling rather than inside-to-outside, meaning attached homes are more airtight than the test says. Consequences: not accounting for this risks under-ventilation and misclassifying homes as suitable for natural ventilation. When the measured airtightness replaced the EPC default for 11 case study homes the energy efficiency rating improved, showing EPC default airtightness values were over-estimating air leakage, and using the co-pressurisation value gained a further rating point; the improvements equated to reductions of 5 per cent in predicted annual carbon emissions, 8 per cent in space heating demand and 3 per cent in fuel bills. The paper concludes the elevated pressures of the test itself create leakage paths not present in normal use, which affects the accuracy of fan pressurisation in attached homes and its use for regulatory compliance, ventilation decisions and energy models.
- fair RN-MZ1HY9
Leeds Beckett University, Leeds Sustainability Institute
Coheating test results from 25 new build dwellings built to Part L1A 2006 or better, the study that put a number on the fabric performance gap. The mean measured whole building U-value was just over 1.6 times greater than predicted, and for individual dwellings the gap between measured and predicted fabric performance could exceed 100 per cent, varying with dwelling form and construction type. Context: dwellings account for just under 30 per cent of the UK's total CO2 emissions, against a national target of an 80 per cent cut by 2050 on 1990 levels; around 80 to 85 per cent of the dwellings that will be in use in 2050 already exist. The practical implication for a homeowner is that a design SAP figure or an EPC is a prediction, not a measurement, and a real house can lose over half as much heat again as the paperwork says.
- fair RN-SXETCQ
Leeds Beckett University, Leeds Sustainability Institute
Measured the improvement from insulating a suspended timber ground floor two different ways and found the answer depends on the method. Aggregate whole-house measurement gave a U-value improvement of 0.55 W/m2K; disaggregated spot heat flux density measurements on the floor gave 0.89 W/m2K for the same retrofit. The conclusion is that disaggregated spot measurements may over-estimate the benefit of fabric retrofits and that aggregate methods are the more appropriate evaluation tool, which is directly relevant to any quoted saving derived from a spot heat flux reading. The paper also concludes that Energy Performance Certificates are unlikely to give a reliable estimate of energy savings because they rely on default assumptions for fabric U-values and ventilation rates, with consequences both for policy evaluation and for householders who may be excluded from financial support on the strength of an EPC figure.
- fair RN-JSWD0V
Leeds Beckett University, Leeds Sustainability Institute
The method statement for the coheating test, which is how whole-house heat loss is actually measured rather than modelled. The dwelling is left unoccupied and heated electrically by portable point heaters to a mean elevated internal temperature, typically 25 C, held over a number of days, with data collected 24 hours a day; a test typically runs for 1 to 4 weeks once the dwelling is heat saturated. Daily heat input in Watts is plotted against the temperature difference between inside and outside, and the slope of that plot gives the raw uncorrected heat loss coefficient in W/K, which combines fabric heat loss and background ventilation loss. It is a quasi-steady state aggregate method, one of only a few capable of measuring whole dwelling heat loss in situ (the alternative named is the PSTAR method), and it has existed since the 1970s. Practical cautions given: solar radiation absorbed one day may not be re-emitted until the next, and in a very airtight dwelling the ventilation rate can be so low that it takes 2 to 3 days for all the air in the dwelling to be exchanged.
- fair RN-DQNN2W
Leeds Beckett University, Leeds Sustainability Institute (for BEIS)
Measured comparison of thin internal wall insulation (TIWI) against conventional internal wall insulation on solid brick walls, using coheating tests for the whole-house heat transfer coefficient in W/K plus dynamic simulation for bills. Findings with numbers: TIWI is only 20 to 30 per cent of the thickness of conventional IWI and gives U-values between 0.8 and 1.4 W/m2K on solid brick, yet delivers between 40 and 70 per cent of the fuel bill savings conventional IWI achieves. Diminishing returns are stark: conventional IWI was in some cases four times thicker than TIWI yet gave only 22 per cent more benefit. TIWI can take up to a third less floor area than conventional IWI, and TIWI products needing no decoration were the cheapest to install, though some require multiple visits which raises labour cost. Moisture caution stated plainly: neither IWI nor TIWI removes moisture risk, both can increase condensation risk on adjacent surfaces and in neighbouring homes, and both must be fitted to walls in good repair. Policy context: solid wall insulation appears in only around 7 per cent of ECO retrofits and IWI accounts for less than 1 per cent of ECO measures; the report argues the 0.3 W/m2K target for solid walls deters uptake, noting cavity wall retrofits are allowed 0.55 W/m2K.
- fair RN-S600R5
London Fire Brigade
Lithium ion battery fire risk in the home, relevant to home battery storage, e-bike charging in a garage or utility room and site tool charging. Batteries present a fire risk when overcharged, short circuited, submerged in water or physically damaged. Practical rules: use the charger supplied with the device, and if replacing it buy a branded genuine product from a trusted supplier because counterfeit chargers often fail UK safety regulations; avoid storing, using or charging at very high or low temperatures; protect cells from crushing, puncture and immersion; do not leave items on charge after the cycle completes, so not overnight; never cover a charger or charging device, including using a laptop power lead in bed; and do not overload sockets. If a battery starts swelling or expanding, stop charging immediately, turn the device off and do not remove the casing or tamper with it.
- fair RN-SB31PB
Loughborough University
Analysis of existing boiler monitoring data from around 4,600 homes to test how many are heat pump ready without works. Findings: 31 per cent of monitored dwellings could run a low temperature heat pump with no radiator upgrades at all, and around two thirds could take a high temperature heat pump. This directly contradicts earlier government analysis based on building surveys, which concluded that almost all homes would need radiator upgrades. The research argues many existing emitter systems are already fit for purpose, which substantially lowers the predicted cost and disruption of a heat pump retrofit and identifies more precisely which dwellings genuinely need improving first. Led by Dr Stephen Watson at Loughborough's School of Architecture, Building and Civil Engineering with lead author Laurence Childs of the UCL Energy Institute, published January 2025.
- fair RN-DQ8S9B
MoneyHelper (Money and Pensions Service)
Four step method for funding a renovation from the government backed money guidance body. Step one: list everything wanted and ask for written quotes rather than estimates, drawing the distinction that a quotation is an agreed fixed price while an estimate is an approximate price that can change; get at least three quotes, compare them in detail, check reviews, and insist on a written costed agreement, with any extra work priced in a written estimate and a revised costed schedule before it is authorised. Step two: pay from savings where possible while keeping a reserve for unexpected costs. Step three: compare the total cost of borrowing over the shortest period, not just the headline rate, and note that a 0% purchase or balance transfer credit card suits small jobs, that tradespeople may not take cards, and that card purchases of parts can attract Section 75 protection. Step four: use the EPC to identify improvements, and check the Warm Homes local grant, the Boiler Upgrade Scheme for heat pumps and biomass, Warmer Homes Scotland (owned or privately rented for at least a year plus qualifying benefits, with an interest free loan alternative), and the Welsh Nest scheme. States that owner occupiers and private tenants with a household income below £23,000 may qualify for grants of up to £7,500, or even £10,000, towards insulation, heating and window glazing.
- fair RN-RYFUP3
National Energy Action
National Energy Action's free service for householders in England and Wales, covering energy bills, keeping warm and healthy at home, plus benefits advice and income maximisation, and offering advice workshops to householders and training to frontline staff. The helpline is 0800 304 7159, with SignVideo, open Monday to Thursday 10am to 4pm and Friday 10am to 12:30pm, with BSL interpreter routes for both energy and benefits advice.
- fair RN-2RGEMP
NHS
The clinical authority for what carbon monoxide does and how many alarms a home needs. Lists symptoms as headache, dizziness, nausea or vomiting, weakness, tiredness and confusion, chest and muscle pain, shortness of breath, flushing and loss of vision, and notes the tell-tale pattern that symptoms worsen in an affected room and improve on leaving the building. Names the appliances that can produce carbon monoxide when badly installed, faulty or poorly maintained: gas boilers, gas cookers and clay ovens, gas or paraffin heaters, wood, gas and coal fires and portable generators, plus barbecues or camping stoves used indoors and engines run in a garage. The prevention advice is specific: get a carbon monoxide alarm for each room of the home containing an appliance that burns gas, oil, coal or wood, have appliances properly installed and serviced regularly by a qualified and registered engineer, and keep chimneys and flues clear. Directs readers to call NHS 111 for suspected poisoning and 999 for breathing difficulty, sudden confusion or loss of consciousness.
- fair RN-VSZ4J2
NHS
Relevant to a property left empty during works or a newly commissioned hot water system. Legionnaires' disease is caught by inhaling tiny water droplets carrying the bacteria, from air conditioning systems, humidifiers, spa pools and hot tubs, and taps and showers that are not used often. It is usually picked up in hotels, hospitals or offices where the bacteria have entered the water supply, and is less commonly caught at home. It is not usually caught by drinking contaminated water, from other people, or from ponds, lakes and rivers. Symptoms include a cough lasting 3 weeks or more; travel and stays in the last 10 days should be reported to a doctor, and antibiotic treatment usually lasts 1 to 3 weeks.
- fair RN-E3OXG7
Northern Gas Networks
The three reconnection options after a meter move, which decide whether you also need to book your own Gas Safe engineer. Full reconnection: NGN disconnects the meter, moves it and reconnects internal pipework and appliances, available only where no more than 2 metres of internal (copper outlet) pipework is required, and a representative may visit first to confirm. Partial reconnection: NGN moves the meter but does not reconnect internal pipework, which applies where more than 2 metres of internal pipework is needed, and the customer must arrange a Gas Safe registered engineer. No reconnection: NGN moves neither meter nor connections, which applies when changing to or from a semi-concealed meter box or when the customer is arranging reconnection separately; in that case an Ofgem Approved Meter Installer (OAMI) is needed to reconnect the meter to the service pipe. Customers can opt to do their own excavations or install the meter boxes, but that must be done before the planned start date. Connections Team 0800 040 7766 option 2. Annual gas load is calculated as hourly gas load x usage hours per day x usage days per week x usage weeks per year.
- fair RN-35PT02
Northern Gas Networks
The information the application form actually demands, which is what delays most gas alterations. The applicant must give the distance in metres between the existing and proposed positions, always rounded up to the nearest metre, and an annual gas load estimate calculated as hourly load times hours used per week times number of weeks in the year. The reconnection choice must be made on the form: full reconnection where no more than 2 metres of internal pipework is needed, with NGN disconnecting, moving and reconnecting the meter, pipework and appliances, subject to a possible site visit to confirm; partial reconnection where more than 2 metres of internal pipework is needed, with the customer arranging a Gas Safe registered engineer to reconnect; or no reconnection, which applies when changing to or from a semi-concealed meter box or when arranging reconnection separately, in which case an Ofgem-Approved Meter Installer must be engaged to reconnect the meter to the service pipe and internal pipework, and the gas supplier contacted if the meter itself is changing.
- fair RN-HH84ZN
Northern Gas Networks
Timescales and the easement trap. After acceptance and payment NGN has up to 20 working days to review the works and contact the customer with a proposed start date. Reinstatement of most surfaces takes up to 5 working days after the pipe work finishes. Where a gas main or pipeline must be laid, a legal easement has to be granted first: the easement strip carries restrictions, and specifically buildings cannot be placed over the strip; the process runs between NGN's solicitors and the customer's, the easement is registrable at the Land Registry, and the legal process takes on average 4 to 8 weeks. Moving the position of a meter or the service pipe is not DIY work; the Connections team handles quotation, design, alteration and reconnection, and a separate advice route exists for diverting a gas main.
- fair RN-FAG5UZ
Northern Powergrid
When an extension or a new low carbon technology forces a supply change rather than just new circuits. The named triggers for increasing or decreasing capacity or changing the size of the main fuse are adding new rooms, extensions, electric vehicle chargers, heat pumps, or additional appliances. Applications need a site location plan, submitted through the online mapping tool or as an Ordnance Survey or Land Registry plan. Three parties are always involved in moving an electrical service: Northern Powergrid moves the service cable and mains fuse, the electricity supplier moves the meter and must be booked to attend on the day of the works, and a qualified electrician handles anything on the customer's own internal wiring.
- fair RN-9T2LVP
Scottish Water
SCOTLAND. Plumbing and water fittings in Scotland are governed by the Water Byelaws enforced by Scottish Water, not by the Water Supply (Water Fittings) Regulations 1999 that apply in England and Wales, so an England-based note on notifiable plumbing work, backflow protection or fittings approval names the wrong instrument for a Scottish job. The page is Scottish Water's entry point for the Water Byelaws that protect water quality and for the separate trade effluent consent system covering waste water discharged to the public sewer by a business.